... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Mini S.4\. Monitoring.WebHome
1 +Battery management systems.BMS Mini S.4\. Monitoring.WebHome
Content
... ... @@ -186,12 +186,34 @@
186 186  
187 187  Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → Sunny Island inverter " section:
188 188  
189 -[[image:1733755874628-796.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="800"]]
189 +[[image:1740651146561-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]]
190 190  
191 191  In this section:
192 192  
193 -* Voltage, V.
193 +* Enable – a flag to enable communication with the inverter;
194 +* CAN port – port which is used to communicate with the inverter:
195 +** CAN1 (ext);
196 +** CAN2 (int);
197 +* Receive timeout – a timeout for receiving packets from the inverter (if no data is being received from the inverter during this time, the connection loss flag is set), millisecond;
198 +* Output period – a period of sending commands to the inverter, millisecond;
199 +* Charge voltage, V – maximum charging voltage, V;
200 +* Charge current, А – maximum charging current, A;
201 +* Discharge voltage (min) – minimum discharging voltage, V;
202 +* Discharge current – maximum discharging current, А;
203 +* Invert current – a flag to inverse current sent to the inverter;
194 194  
205 +When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current.
206 +
207 +=== Pylontech inverter ===
208 +
209 +To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
210 +
211 +[[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]]
212 +
213 +In this section:
214 +
215 +* Online – a flag of normal communication with the inverter;
216 +
195 195  === HYG Class I-III truck ===
196 196  
197 197  Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
1740651146561-123.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +22.5 KB
Content
1740651353463-581.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +11.1 KB
Content
1740651484968-315.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content