Wiki source code of 4.1 Signals
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
1.1 | 1 | (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) |
2 | = Monitoring = | ||
3 | |||
4 | (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
5 | == Signals == | ||
6 | |||
7 | States of the device's discrete inputs are available in the "Signals → Input discrete signal" section: | ||
8 | |||
9 | [[image:1733755484212-704.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="235" width="800"]] | ||
10 | |||
11 | In this section: | ||
12 | |||
13 | * Battery cover – a signal from the battery cover; | ||
14 | * Charger connected – a signal indicating that the charger is connected to the battery; | ||
15 | * Power up/down request – a signal to power up or power down the BMS; | ||
16 | * Inhibit charging – a command to inhibit closing the charging contactor; | ||
17 | * Inhibit discharging – a command to inhibit closing the discharging contactor; | ||
18 | * Insulation status – a signal from an external insulation monitoring device; | ||
19 | * Charge request – a request for closing the charging contactor; | ||
20 | * Precharge request – a request for closing the precharging contactor; | ||
21 | * Discharge request – a request for closing the discharging contactor; | ||
22 | |||
23 | States of the device's discrete outputs are available in the "Signals → Output discrete signals" section: | ||
24 | |||
25 | [[image:1733755484215-785.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="235" width="800"]] | ||
26 | |||
27 | In this section: | ||
28 | |||
29 | * Output #1 - Output #4 – states of the outputs 1-4 respectively. | ||
30 | |||
31 | States of the device's MOSFET switches are available in the "Signals → MOSFETs" section: | ||
32 | |||
33 | [[image:1733755484216-617.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="235" width="800"]] | ||
34 | |||
35 | In this section: | ||
36 | |||
37 | * MOSFET #1 - MOSFET #4 – states of the MOSFET switches 1-4 respectively. | ||
38 | |||
39 | States of the device's contactors feedback signals are available in the "Signals → Contactors feedback" section: | ||
40 | |||
41 | [[image:1733755484218-937.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] | ||
42 | |||
43 | In this section: | ||
44 | |||
45 | * Feedback #1 - Feedback #4 – states of the contactor 1-4 feedback respectively. | ||
46 | |||
47 | === Current sensor === | ||
48 | |||
49 | State of the current sensors is available in the "Signals → Current sensor" section: | ||
50 | |||
51 | [[image:1733755484219-568.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="91" width="800"]] | ||
52 | |||
53 | In this section: | ||
54 | |||
55 | * Current sensor signal – output signal from the current sensor, V; | ||
56 | * Auxiliary line – signal in the auxiliary line, V. | ||
57 | * BMS consumption – current consumption of the BMS, A. | ||
58 | |||
59 | === Shunt sensor === | ||
60 | |||
61 | State of the shunt sensor is available in the "Signals → Shunt sensor" section: | ||
62 | |||
63 | [[image:1733755484220-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] | ||
64 | |||
65 | In this section: | ||
66 | |||
67 | * Online – a flag showing that the communication with the BMS Current Sensor is established; | ||
68 | * Errors – a list of internal errors of the shunt sensor; | ||
69 | * Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz); | ||
70 | * Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); | ||
71 | * Temperature – a temperature of the shunt sensor, °C. |