Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -459,10 +459,11 @@ 459 459 460 460 In this section: 461 461 462 -* Enable – a flag to enable communication with the ZiK truck; 463 -* Node ID – a ZiK identifier in the CANopen network; 464 -* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 465 -* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 462 +* Settings: 463 +** Enable – a flag to enable communication with the ZiK truck; 464 +** Node ID – a ZiK identifier in the CANopen network; 465 +** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 466 +** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 466 466 467 467 The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds. 468 468 ... ... @@ -486,34 +486,6 @@ 486 486 * Receive vehicle messages – a flag to activate receiving vehicle messages; 487 487 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 488 488 489 -=== Bender iso165C === 490 - 491 -To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 492 - 493 -[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 494 - 495 -In this section: 496 - 497 -* Enable – a flag to enable communication with the IMD; 498 -* Receive timeout – a timeout for receiving packets from the IMD, millisecond; 499 -* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning; 500 -* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 501 -* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 502 - 503 -=== BMS IMD === 504 - 505 -To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 506 - 507 -[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 508 - 509 -In this section: 510 - 511 -* Enable – a flag to enable communication with the IMD; 512 -* Node ID – a CANopen address of the BMS IMD device; 513 -* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings; 514 -* Threshold to detect insulation alarm, Ohm; 515 -* Threshold to detect insulation warning, Ohm. 516 - 517 517 === Main X === 518 518 519 519 The BMS Mini device can connect to BMS Main X strings controller.
- 1740580850472-138.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.3 KB - Content
- 1740580889560-625.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content