... ... @@ -272,8 +272,10 @@
272 272  
273 273  To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section:
274 274  
275 -[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section:
275 +[[image:1740580507794-408.png]]
276 276  
277 +In this section:
278 +
277 277  * Enable – a flag to enable communication with the bank;
278 278  * Number of discharge cycles;
279 279  * Minimum voltage of charged cells, V;
... ... @@ -333,7 +333,7 @@
333 333  
334 334  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
335 335  
336 -[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]
338 +[[image:1733753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
337 337  
338 338  In this section:
339 339  
... ... @@ -343,7 +343,6 @@
343 343  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
344 344  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
345 345  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
346 -* Do not set the "Combilift offline" error on the "Charger connected" signal;
347 347  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
348 348  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
349 349  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -451,6 +451,13 @@
451 451  After changing the settings, restart the BMS Mini device.
452 452  )))
453 453  
455 +=== ===
456 +
457 +(% class="box infomessage" %)
458 +(((
459 +
460 +)))
461 +
454 454  === ZiK truck ===
455 455  
456 456  To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section:
... ... @@ -459,10 +459,11 @@
459 459  
460 460  In this section:
461 461  
462 -* Enable – a flag to enable communication with the ZiK truck;
463 -* Node ID – a ZiK identifier in the CANopen network;
464 -* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
465 -* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
470 +* Settings:
471 +** Enable – a flag to enable communication with the ZiK truck;
472 +** Node ID – a ZiK identifier in the CANopen network;
473 +** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
474 +** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
466 466  
467 467  The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds.
468 468  
... ... @@ -486,34 +486,6 @@
486 486  * Receive vehicle messages – a flag to activate receiving vehicle messages;
487 487  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
488 488  
489 -=== Bender iso165C ===
490 -
491 -To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
492 -
493 -[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
494 -
495 -In this section:
496 -
497 -* Enable – a flag to enable communication with the IMD;
498 -* Receive timeout – a timeout for receiving packets from the IMD, millisecond;
499 -* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning;
500 -* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
501 -* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
502 -
503 -=== BMS IMD ===
504 -
505 -To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
506 -
507 -[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
508 -
509 -In this section:
510 -
511 -* Enable – a flag to enable communication with the IMD;
512 -* Node ID – a CANopen address of the BMS IMD device;
513 -* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings;
514 -* Threshold to detect insulation alarm, Ohm;
515 -* Threshold to detect insulation warning, Ohm.
516 -
517 517  === Main X ===
518 518  
519 519  The BMS Mini device can connect to BMS Main X strings controller.
1740580581620-608.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -30.2 KB
Content
1740580850472-138.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -18.3 KB
Content
1740580889560-625.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content