... ... @@ -487,40 +487,6 @@
487 487  * Receive vehicle messages – a flag to activate receiving vehicle messages;
488 488  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
489 489  
490 -=== Bender iso165C ===
491 -
492 -To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
493 -
494 -[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
495 -
496 -In this section:
497 -
498 -* Enable – a flag to enable communication with the IMD;
499 -* CAN port – port which is used to communicate with the vehicle:
500 -** CAN1 (ext);
501 -** CAN2 (int);
502 -* Receive timeout – a timeout for receiving packets from the IMD, millisecond;
503 -* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning;
504 -* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
505 -* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
506 -
507 -=== BMS IMD ===
508 -
509 -To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
510 -
511 -[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
512 -
513 -In this section:
514 -
515 -* Enable – a flag to enable communication with the IMD;
516 -* CAN port – port which is used to communicate with the vehicle:
517 -** CAN1 (ext);
518 -** CAN2 (int);
519 -* Node ID – a CANopen address of the BMS IMD device;
520 -* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings;
521 -* Threshold to detect insulation alarm, Ohm;
522 -* Threshold to detect insulation warning, Ohm.
523 -
524 524  === Main X ===
525 525  
526 526  The BMS Mini device can connect to BMS Main X strings controller.
1740580889560-625.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content