Changes for page 3.5 External equipment

Last modified by Admin on 2025/02/26 17:09

From version 8.2
edited by Admin
on 2025/02/26 14:41
Change comment: There is no comment for this version
To version 5.1
edited by Admin
on 2025/02/26 14:36
Change comment: Загрузить новое вложение 1740580581620-608.png

Summary

Details

Page properties
Content
... ... @@ -272,8 +272,10 @@
272 272  
273 273  To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section:
274 274  
275 -[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section:
275 +[[image:1740580507794-408.png]]
276 276  
277 +In this section:
278 +
277 277  * Enable – a flag to enable communication with the bank;
278 278  * Number of discharge cycles;
279 279  * Minimum voltage of charged cells, V;
... ... @@ -333,7 +333,7 @@
333 333  
334 334  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
335 335  
336 -[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]
338 +[[image:1733753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
337 337  
338 338  In this section:
339 339  
... ... @@ -343,7 +343,6 @@
343 343  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
344 344  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
345 345  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
346 -* Do not set the "Combilift offline" error on the "Charger connected" signal;
347 347  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
348 348  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
349 349  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -451,6 +451,13 @@
451 451  After changing the settings, restart the BMS Mini device.
452 452  )))
453 453  
455 +=== ===
456 +
457 +(% class="box infomessage" %)
458 +(((
459 +
460 +)))
461 +
454 454  === ZiK truck ===
455 455  
456 456  To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section:
... ... @@ -487,40 +487,6 @@
487 487  * Receive vehicle messages – a flag to activate receiving vehicle messages;
488 488  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
489 489  
490 -=== Bender iso165C ===
491 -
492 -To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
493 -
494 -[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
495 -
496 -In this section:
497 -
498 -* Enable – a flag to enable communication with the IMD;
499 -* CAN port – port which is used to communicate with the vehicle:
500 -** CAN1 (ext);
501 -** CAN2 (int);
502 -* Receive timeout – a timeout for receiving packets from the IMD, millisecond;
503 -* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning;
504 -* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
505 -* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
506 -
507 -=== BMS IMD ===
508 -
509 -To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
510 -
511 -[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
512 -
513 -In this section:
514 -
515 -* Enable – a flag to enable communication with the IMD;
516 -* CAN port – port which is used to communicate with the vehicle:
517 -** CAN1 (ext);
518 -** CAN2 (int);
519 -* Node ID – a CANopen address of the BMS IMD device;
520 -* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings;
521 -* Threshold to detect insulation alarm, Ohm;
522 -* Threshold to detect insulation warning, Ohm.
523 -
524 524  === Main X ===
525 525  
526 526  The BMS Mini device can connect to BMS Main X strings controller.
1740580850472-138.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -18.3 KB
Content
1740580889560-625.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content