Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -459,11 +459,10 @@ 459 459 460 460 In this section: 461 461 462 -* Settings: 463 -** Enable – a flag to enable communication with the ZiK truck; 464 -** Node ID – a ZiK identifier in the CANopen network; 465 -** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 466 -** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 462 +* Enable – a flag to enable communication with the ZiK truck; 463 +* Node ID – a ZiK identifier in the CANopen network; 464 +* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 465 +* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 467 467 468 468 The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds. 469 469 ... ... @@ -487,6 +487,34 @@ 487 487 * Receive vehicle messages – a flag to activate receiving vehicle messages; 488 488 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 489 489 489 +=== Bender iso165C === 490 + 491 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 492 + 493 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 494 + 495 +In this section: 496 + 497 +* Enable – a flag to enable communication with the IMD; 498 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond; 499 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning; 500 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 501 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 502 + 503 +=== BMS IMD === 504 + 505 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 506 + 507 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 508 + 509 +In this section: 510 + 511 +* Enable – a flag to enable communication with the IMD; 512 +* Node ID – a CANopen address of the BMS IMD device; 513 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings; 514 +* Threshold to detect insulation alarm, Ohm; 515 +* Threshold to detect insulation warning, Ohm. 516 + 490 490 === Main X === 491 491 492 492 The BMS Mini device can connect to BMS Main X strings controller.
- 1740580889560-625.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content