Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -272,8 +272,10 @@ 272 272 273 273 To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 274 274 275 -[[image:1740580507794-408.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section:275 +[[image:1740580507794-408.png]] 276 276 277 +In this section: 278 + 277 277 * Enable – a flag to enable communication with the bank; 278 278 * Number of discharge cycles; 279 279 * Minimum voltage of charged cells, V; ... ... @@ -333,7 +333,7 @@ 333 333 334 334 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 335 335 336 -[[image:17 40580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]338 +[[image:1733753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]] 337 337 338 338 In this section: 339 339 ... ... @@ -343,7 +343,6 @@ 343 343 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 344 344 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 345 345 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 346 -* Do not set the "Combilift offline" error on the "Charger connected" signal; 347 347 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 348 348 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 349 349 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift; ... ... @@ -451,6 +451,13 @@ 451 451 After changing the settings, restart the BMS Mini device. 452 452 ))) 453 453 455 +=== === 456 + 457 +(% class="box infomessage" %) 458 +((( 459 + 460 +))) 461 + 454 454 === ZiK truck === 455 455 456 456 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section:
- 1740580581620-608.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -30.2 KB - Content
- 1740580850472-138.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.3 KB - Content