Changes for page 3.5 External equipment

Last modified by Admin on 2025/02/26 17:09

From version 7.1
edited by Admin
on 2025/02/26 14:40
Change comment: Загрузить новое вложение 1740580850472-138.png
To version 4.2
edited by Admin
on 2025/02/26 14:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -272,8 +272,10 @@
272 272  
273 273  To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section:
274 274  
275 -[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section:
275 +[[image:1740580507794-408.png]]
276 276  
277 +In this section:
278 +
277 277  * Enable – a flag to enable communication with the bank;
278 278  * Number of discharge cycles;
279 279  * Minimum voltage of charged cells, V;
... ... @@ -333,7 +333,7 @@
333 333  
334 334  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
335 335  
336 -[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]
338 +[[image:1733753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
337 337  
338 338  In this section:
339 339  
... ... @@ -343,7 +343,6 @@
343 343  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
344 344  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
345 345  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
346 -* Do not set the "Combilift offline" error on the "Charger connected" signal;
347 347  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
348 348  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
349 349  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -451,6 +451,13 @@
451 451  After changing the settings, restart the BMS Mini device.
452 452  )))
453 453  
455 +=== ===
456 +
457 +(% class="box infomessage" %)
458 +(((
459 +
460 +)))
461 +
454 454  === ZiK truck ===
455 455  
456 456  To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: