... ... @@ -487,6 +487,40 @@
487 487  * Receive vehicle messages – a flag to activate receiving vehicle messages;
488 488  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
489 489  
490 +=== Bender iso165C ===
491 +
492 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
493 +
494 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
495 +
496 +In this section:
497 +
498 +* Enable – a flag to enable communication with the IMD;
499 +* CAN port – port which is used to communicate with the vehicle:
500 +** CAN1 (ext);
501 +** CAN2 (int);
502 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond;
503 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning;
504 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
505 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
506 +
507 +=== BMS IMD ===
508 +
509 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
510 +
511 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
512 +
513 +In this section:
514 +
515 +* Enable – a flag to enable communication with the IMD;
516 +* CAN port – port which is used to communicate with the vehicle:
517 +** CAN1 (ext);
518 +** CAN2 (int);
519 +* Node ID – a CANopen address of the BMS IMD device;
520 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings;
521 +* Threshold to detect insulation alarm, Ohm;
522 +* Threshold to detect insulation warning, Ohm.
523 +
490 490  === Main X ===
491 491  
492 492  The BMS Mini device can connect to BMS Main X strings controller.
1740580850472-138.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.3 KB
Content
1740580889560-625.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content