Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -451,13 +451,6 @@ 451 451 After changing the settings, restart the BMS Mini device. 452 452 ))) 453 453 454 -=== === 455 - 456 -(% class="box infomessage" %) 457 -((( 458 - 459 -))) 460 - 461 461 === ZiK truck === 462 462 463 463 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: ... ... @@ -466,11 +466,10 @@ 466 466 467 467 In this section: 468 468 469 -* Settings: 470 -** Enable – a flag to enable communication with the ZiK truck; 471 -** Node ID – a ZiK identifier in the CANopen network; 472 -** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 473 -** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 462 +* Enable – a flag to enable communication with the ZiK truck; 463 +* Node ID – a ZiK identifier in the CANopen network; 464 +* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 465 +* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 474 474 475 475 The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds. 476 476 ... ... @@ -494,6 +494,34 @@ 494 494 * Receive vehicle messages – a flag to activate receiving vehicle messages; 495 495 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 496 496 489 +=== Bender iso165C === 490 + 491 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 492 + 493 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 494 + 495 +In this section: 496 + 497 +* Enable – a flag to enable communication with the IMD; 498 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond; 499 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning; 500 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 501 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 502 + 503 +=== BMS IMD === 504 + 505 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 506 + 507 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 508 + 509 +In this section: 510 + 511 +* Enable – a flag to enable communication with the IMD; 512 +* Node ID – a CANopen address of the BMS IMD device; 513 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings; 514 +* Threshold to detect insulation alarm, Ohm; 515 +* Threshold to detect insulation warning, Ohm. 516 + 497 497 === Main X === 498 498 499 499 The BMS Mini device can connect to BMS Main X strings controller.
- 1740580850472-138.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.3 KB - Content
- 1740580889560-625.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content