Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -451,13 +451,6 @@ 451 451 After changing the settings, restart the BMS Mini device. 452 452 ))) 453 453 454 -=== === 455 - 456 -(% class="box infomessage" %) 457 -((( 458 - 459 -))) 460 - 461 461 === ZiK truck === 462 462 463 463 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: ... ... @@ -494,6 +494,40 @@ 494 494 * Receive vehicle messages – a flag to activate receiving vehicle messages; 495 495 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 496 496 490 +=== Bender iso165C === 491 + 492 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 493 + 494 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 495 + 496 +In this section: 497 + 498 +* Enable – a flag to enable communication with the IMD; 499 +* CAN port – port which is used to communicate with the vehicle: 500 +** CAN1 (ext); 501 +** CAN2 (int); 502 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond; 503 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning; 504 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 505 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 506 + 507 +=== BMS IMD === 508 + 509 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 510 + 511 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 512 + 513 +In this section: 514 + 515 +* Enable – a flag to enable communication with the IMD; 516 +* CAN port – port which is used to communicate with the vehicle: 517 +** CAN1 (ext); 518 +** CAN2 (int); 519 +* Node ID – a CANopen address of the BMS IMD device; 520 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings; 521 +* Threshold to detect insulation alarm, Ohm; 522 +* Threshold to detect insulation warning, Ohm. 523 + 497 497 === Main X === 498 498 499 499 The BMS Mini device can connect to BMS Main X strings controller.
- 1740580850472-138.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.3 KB - Content
- 1740580889560-625.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content