Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -272,10 +272,8 @@ 272 272 273 273 To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 274 274 275 -[[image:1740580507794-408.png]] 275 +[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section: 276 276 277 -In this section: 278 - 279 279 * Enable – a flag to enable communication with the bank; 280 280 * Number of discharge cycles; 281 281 * Minimum voltage of charged cells, V; ... ... @@ -335,7 +335,7 @@ 335 335 336 336 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 337 337 338 -[[image:17 33753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]336 +[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]] 339 339 340 340 In this section: 341 341 ... ... @@ -345,6 +345,7 @@ 345 345 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 346 346 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 347 347 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 346 +* Do not set the "Combilift offline" error on the "Charger connected" signal; 348 348 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 349 349 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 350 350 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift; ... ... @@ -452,13 +452,6 @@ 452 452 After changing the settings, restart the BMS Mini device. 453 453 ))) 454 454 455 -=== === 456 - 457 -(% class="box infomessage" %) 458 -((( 459 - 460 -))) 461 - 462 462 === ZiK truck === 463 463 464 464 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: ... ... @@ -467,11 +467,10 @@ 467 467 468 468 In this section: 469 469 470 -* Settings: 471 -** Enable – a flag to enable communication with the ZiK truck; 472 -** Node ID – a ZiK identifier in the CANopen network; 473 -** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 474 -** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 462 +* Enable – a flag to enable communication with the ZiK truck; 463 +* Node ID – a ZiK identifier in the CANopen network; 464 +* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 465 +* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 475 475 476 476 The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds. 477 477 ... ... @@ -495,6 +495,34 @@ 495 495 * Receive vehicle messages – a flag to activate receiving vehicle messages; 496 496 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 497 497 489 +=== Bender iso165C === 490 + 491 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 492 + 493 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 494 + 495 +In this section: 496 + 497 +* Enable – a flag to enable communication with the IMD; 498 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond; 499 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning; 500 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 501 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 502 + 503 +=== BMS IMD === 504 + 505 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 506 + 507 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 508 + 509 +In this section: 510 + 511 +* Enable – a flag to enable communication with the IMD; 512 +* Node ID – a CANopen address of the BMS IMD device; 513 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings; 514 +* Threshold to detect insulation alarm, Ohm; 515 +* Threshold to detect insulation warning, Ohm. 516 + 498 498 === Main X === 499 499 500 500 The BMS Mini device can connect to BMS Main X strings controller.
- 1740580850472-138.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.3 KB - Content
- 1740580889560-625.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content