273 273  To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section:
274 274  
275 -[[image:1740580507794-408.png]]
275 +[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section:
276 276  
277 -In this section:
278 -
279 279  * Enable – a flag to enable communication with the bank;
280 280  * Number of discharge cycles;
281 281  * Minimum voltage of charged cells, V;
... ... @@ -335,7 +335,7 @@
335 335  
336 336  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
337 337  
338 -[[image:1733753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
336 +[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]
339 339  
340 340  In this section:
341 341  
... ... @@ -345,6 +345,7 @@
345 345  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
346 346  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
347 347  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
346 +* Do not set the "Combilift offline" error on the "Charger connected" signal;
348 348  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
349 349  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
350 350  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -452,13 +452,6 @@
452 452  After changing the settings, restart the BMS Mini device.
453 453  )))
454 454  
455 -=== ===
456 -
457 -(% class="box infomessage" %)
458 -(((
459 -
460 -)))
461 -
462 462  === ZiK truck ===
463 463  
464 464  To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section:
... ... @@ -467,11 +467,10 @@
467 467  
468 468  In this section:
469 469  
470 -* Settings:
471 -** Enable – a flag to enable communication with the ZiK truck;
472 -** Node ID – a ZiK identifier in the CANopen network;
473 -** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
474 -** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
462 +* Enable – a flag to enable communication with the ZiK truck;
463 +* Node ID – a ZiK identifier in the CANopen network;
464 +* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
465 +* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
475 475  
476 476  The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds.
477 477  
... ... @@ -495,6 +495,34 @@
495 495  * Receive vehicle messages – a flag to activate receiving vehicle messages;
496 496  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
497 497  
489 +=== Bender iso165C ===
490 +
491 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
492 +
493 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
494 +
495 +In this section:
496 +
497 +* Enable – a flag to enable communication with the IMD;
498 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond;
499 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning;
500 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
501 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
502 +
503 +=== BMS IMD ===
504 +
505 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
506 +
507 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
508 +
509 +In this section:
510 +
511 +* Enable – a flag to enable communication with the IMD;
512 +* Node ID – a CANopen address of the BMS IMD device;
513 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings;
514 +* Threshold to detect insulation alarm, Ohm;
515 +* Threshold to detect insulation warning, Ohm.
516 +
498 498  === Main X ===
499 499  
500 500  The BMS Mini device can connect to BMS Main X strings controller.
1740580581620-608.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +30.2 KB
Content
1740580850472-138.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.3 KB
Content
1740580889560-625.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content