Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -232,7 +232,7 @@ 232 232 After changing the settings, restart the BMS Mini device. 233 233 ))) 234 234 235 -=== S MA Sunny Island inverter ===235 +=== Sunny Island inverter === 236 236 237 237 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → inverters → SMA Sunny Island inverter" section: 238 238 ... ... @@ -251,43 +251,6 @@ 251 251 252 252 When working with the Sunny Island inverter, the BMS Mini device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current. 253 253 254 -=== Pylontech inverter === 255 - 256 -To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section: 257 - 258 -[[image:1740580440283-115.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]] 259 - 260 -In this section: 261 - 262 -* Enable – a flag to enable communication with the inverter; 263 -* Type – invertor type: 264 -** Pylontech; 265 -** Solis; 266 -* Charge voltage, V – maximum charging voltage, V; 267 -* Charge current, А – maximum charging current, A; 268 -* Discharge voltage (min) – minimum discharging voltage, V; 269 -* Discharge current – maximum discharging current, А. 270 - 271 -=== ASTOM load bank (cycling) === 272 - 273 -To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 274 - 275 -[[image:1740580507794-408.png]] 276 - 277 -In this section: 278 - 279 -* Enable – a flag to enable communication with the bank; 280 -* Number of discharge cycles; 281 -* Minimum voltage of charged cells, V; 282 -* Voltage deviation of charged cells – minimum allowable deviation of the cells voltage at which battery states as charged, V; 283 -* Maximum discharge current, A; 284 -* Cell voltage to stop discharging, V; 285 -* SOC to be at the end of cycling – target SOC at the end of charge-discharge cycling, V; 286 -* Delay before starting discharging – a delay before transmitting command to the load to start discharging, millisecond; 287 -* Check the difference between the min and max cell voltage – a flag to enable check of difference between the minimum and maximum cell voltages to generate an error; 288 -* Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V; 289 -* Delay before setting the error – a delay before generating an error, second. 290 - 291 291 === HYG Class I-III truck === 292 292 293 293 The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE.
- 1740580440283-115.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.6 KB - Content
- 1740580507794-408.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.4 KB - Content