236 236  
237 237  To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → inverters → SMA Sunny Island inverter" section:
238 238  
239 +[[image:1733753328053-956.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]]
239 239  
240 240  In this section:
241 241  
... ... @@ -254,7 +254,37 @@
254 254  
255 255  To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
256 256  
258 +[[image:1740580440283-115.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]]
257 257  
260 +In this section:
261 +
262 +* Enable – a flag to enable communication with the inverter;
263 +* Type – invertor type:
264 +** Pylontech;
265 +** Solis;
266 +* Charge voltage, V – maximum charging voltage, V;
267 +* Charge current, А – maximum charging current, A;
268 +* Discharge voltage (min) – minimum discharging voltage, V;
269 +* Discharge current – maximum discharging current, А.
270 +
271 +=== ASTOM load bank (cycling) ===
272 +
273 +To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section:
274 +
275 +[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section:
276 +
277 +* Enable – a flag to enable communication with the bank;
278 +* Number of discharge cycles;
279 +* Minimum voltage of charged cells, V;
280 +* Voltage deviation of charged cells – minimum allowable deviation of the cells voltage at which battery states as charged, V;
281 +* Maximum discharge current, A;
282 +* Cell voltage to stop discharging, V;
283 +* SOC to be at the end of cycling – target SOC at the end of charge-discharge cycling, V;
284 +* Delay before starting discharging – a delay before transmitting command to the load to start discharging, millisecond;
285 +* Check the difference between the min and max cell voltage – a flag to enable check of difference between the minimum and maximum cell voltages to generate an error;
286 +* Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V;
287 +* Delay before setting the error – a delay before generating an error, second.
288 +
258 258  === HYG Class I-III truck ===
259 259  
260 260  The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE.
... ... @@ -302,7 +302,7 @@
302 302  
303 303  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
304 304  
305 -[[image:1733753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
336 +[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]
306 306  
307 307  In this section:
308 308  
... ... @@ -312,6 +312,7 @@
312 312  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
313 313  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
314 314  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
346 +* Do not set the "Combilift offline" error on the "Charger connected" signal;
315 315  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
316 316  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
317 317  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -419,13 +419,6 @@
419 419  After changing the settings, restart the BMS Mini device.
420 420  )))
421 421  
422 -=== ===
423 -
424 -(% class="box infomessage" %)
425 -(((
426 -
427 -)))
428 -
429 429  === ZiK truck ===
430 430  
431 431  To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section:
... ... @@ -434,11 +434,10 @@
434 434  
435 435  In this section:
436 436  
437 -* Settings:
438 -** Enable – a flag to enable communication with the ZiK truck;
439 -** Node ID – a ZiK identifier in the CANopen network;
440 -** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
441 -** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
462 +* Enable – a flag to enable communication with the ZiK truck;
463 +* Node ID – a ZiK identifier in the CANopen network;
464 +* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
465 +* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
442 442  
443 443  The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds.
444 444  
... ... @@ -462,6 +462,34 @@
462 462  * Receive vehicle messages – a flag to activate receiving vehicle messages;
463 463  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
464 464  
489 +=== Bender iso165C ===
490 +
491 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
492 +
493 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
494 +
495 +In this section:
496 +
497 +* Enable – a flag to enable communication with the IMD;
498 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond;
499 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning;
500 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
501 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
502 +
503 +=== BMS IMD ===
504 +
505 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
506 +
507 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
508 +
509 +In this section:
510 +
511 +* Enable – a flag to enable communication with the IMD;
512 +* Node ID – a CANopen address of the BMS IMD device;
513 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings;
514 +* Threshold to detect insulation alarm, Ohm;
515 +* Threshold to detect insulation warning, Ohm.
516 +
465 465  === Main X ===
466 466  
467 467  The BMS Mini device can connect to BMS Main X strings controller.
1740580581620-608.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +30.2 KB
Content
1740580850472-138.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.3 KB
Content
1740580889560-625.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content