Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -236,6 +236,7 @@ 236 236 237 237 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → inverters → SMA Sunny Island inverter" section: 238 238 239 +[[image:1733753328053-956.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]] 239 239 240 240 In this section: 241 241 ... ... @@ -254,7 +254,37 @@ 254 254 255 255 To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section: 256 256 258 +[[image:1740580440283-115.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]] 257 257 260 +In this section: 261 + 262 +* Enable – a flag to enable communication with the inverter; 263 +* Type – invertor type: 264 +** Pylontech; 265 +** Solis; 266 +* Charge voltage, V – maximum charging voltage, V; 267 +* Charge current, А – maximum charging current, A; 268 +* Discharge voltage (min) – minimum discharging voltage, V; 269 +* Discharge current – maximum discharging current, А. 270 + 271 +=== ASTOM load bank (cycling) === 272 + 273 +To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 274 + 275 +[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section: 276 + 277 +* Enable – a flag to enable communication with the bank; 278 +* Number of discharge cycles; 279 +* Minimum voltage of charged cells, V; 280 +* Voltage deviation of charged cells – minimum allowable deviation of the cells voltage at which battery states as charged, V; 281 +* Maximum discharge current, A; 282 +* Cell voltage to stop discharging, V; 283 +* SOC to be at the end of cycling – target SOC at the end of charge-discharge cycling, V; 284 +* Delay before starting discharging – a delay before transmitting command to the load to start discharging, millisecond; 285 +* Check the difference between the min and max cell voltage – a flag to enable check of difference between the minimum and maximum cell voltages to generate an error; 286 +* Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V; 287 +* Delay before setting the error – a delay before generating an error, second. 288 + 258 258 === HYG Class I-III truck === 259 259 260 260 The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE. ... ... @@ -302,7 +302,7 @@ 302 302 303 303 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 304 304 305 -[[image:17 33753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]336 +[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]] 306 306 307 307 In this section: 308 308 ... ... @@ -312,6 +312,7 @@ 312 312 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 313 313 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 314 314 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 346 +* Do not set the "Combilift offline" error on the "Charger connected" signal; 315 315 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 316 316 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 317 317 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift; ... ... @@ -419,13 +419,6 @@ 419 419 After changing the settings, restart the BMS Mini device. 420 420 ))) 421 421 422 -=== === 423 - 424 -(% class="box infomessage" %) 425 -((( 426 - 427 -))) 428 - 429 429 === ZiK truck === 430 430 431 431 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: ... ... @@ -434,11 +434,10 @@ 434 434 435 435 In this section: 436 436 437 -* Settings: 438 -** Enable – a flag to enable communication with the ZiK truck; 439 -** Node ID – a ZiK identifier in the CANopen network; 440 -** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 441 -** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 462 +* Enable – a flag to enable communication with the ZiK truck; 463 +* Node ID – a ZiK identifier in the CANopen network; 464 +* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 465 +* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 442 442 443 443 The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds. 444 444 ... ... @@ -462,6 +462,34 @@ 462 462 * Receive vehicle messages – a flag to activate receiving vehicle messages; 463 463 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 464 464 489 +=== Bender iso165C === 490 + 491 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 492 + 493 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 494 + 495 +In this section: 496 + 497 +* Enable – a flag to enable communication with the IMD; 498 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond; 499 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning; 500 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 501 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 502 + 503 +=== BMS IMD === 504 + 505 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 506 + 507 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 508 + 509 +In this section: 510 + 511 +* Enable – a flag to enable communication with the IMD; 512 +* Node ID – a CANopen address of the BMS IMD device; 513 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings; 514 +* Threshold to detect insulation alarm, Ohm; 515 +* Threshold to detect insulation warning, Ohm. 516 + 465 465 === Main X === 466 466 467 467 The BMS Mini device can connect to BMS Main X strings controller.
- 1740580581620-608.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.2 KB - Content
- 1740580850472-138.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.3 KB - Content
- 1740580889560-625.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content