- Content
-
... ... @@ -236,6 +236,7 @@ 236 236 237 237 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → inverters → SMA Sunny Island inverter" section: 238 238 239 +[[image:1733753328053-956.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]] 239 239 240 240 In this section: 241 241 ... ... @@ -254,7 +254,37 @@ 254 254 255 255 To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section: 256 256 258 +[[image:1740580440283-115.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]] 257 257 260 +In this section: 261 + 262 +* Enable – a flag to enable communication with the inverter; 263 +* Type – invertor type: 264 +** Pylontech; 265 +** Solis; 266 +* Charge voltage, V – maximum charging voltage, V; 267 +* Charge current, А – maximum charging current, A; 268 +* Discharge voltage (min) – minimum discharging voltage, V; 269 +* Discharge current – maximum discharging current, А. 270 + 271 +=== ASTOM load bank (cycling) === 272 + 273 +To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 274 + 275 +[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section: 276 + 277 +* Enable – a flag to enable communication with the bank; 278 +* Number of discharge cycles; 279 +* Minimum voltage of charged cells, V; 280 +* Voltage deviation of charged cells – minimum allowable deviation of the cells voltage at which battery states as charged, V; 281 +* Maximum discharge current, A; 282 +* Cell voltage to stop discharging, V; 283 +* SOC to be at the end of cycling – target SOC at the end of charge-discharge cycling, V; 284 +* Delay before starting discharging – a delay before transmitting command to the load to start discharging, millisecond; 285 +* Check the difference between the min and max cell voltage – a flag to enable check of difference between the minimum and maximum cell voltages to generate an error; 286 +* Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V; 287 +* Delay before setting the error – a delay before generating an error, second. 288 + 258 258 === HYG Class I-III truck === 259 259 260 260 The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE. ... ... @@ -302,7 +302,7 @@ 302 302 303 303 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 304 304 305 -[[image:17 33753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]336 +[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]] 306 306 307 307 In this section: 308 308 ... ... @@ -312,6 +312,7 @@ 312 312 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 313 313 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 314 314 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 346 +* Do not set the "Combilift offline" error on the "Charger connected" signal; 315 315 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 316 316 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 317 317 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
- 1740580507794-408.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.4 KB - Content
- 1740580581620-608.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.2 KB - Content