Changes for page 3.5 External equipment

Last modified by Admin on 2025/02/26 17:09

From version 2.2
edited by Admin
on 2025/02/26 14:32
Change comment: There is no comment for this version
To version 7.1
edited by Admin
on 2025/02/26 14:40
Change comment: Загрузить новое вложение 1740580850472-138.png

Summary

Details

Page properties
Content
... ... @@ -232,7 +232,7 @@
232 232  After changing the settings, restart the BMS Mini device.
233 233  )))
234 234  
235 -=== Sunny Island inverter ===
235 +=== SMA Sunny Island inverter ===
236 236  
237 237  To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → inverters → SMA Sunny Island inverter" section:
238 238  
... ... @@ -251,6 +251,41 @@
251 251  
252 252  When working with the Sunny Island inverter, the BMS Mini device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current.
253 253  
254 +=== Pylontech inverter ===
255 +
256 +To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
257 +
258 +[[image:1740580440283-115.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]]
259 +
260 +In this section:
261 +
262 +* Enable – a flag to enable communication with the inverter;
263 +* Type – invertor type:
264 +** Pylontech;
265 +** Solis;
266 +* Charge voltage, V – maximum charging voltage, V;
267 +* Charge current, А – maximum charging current, A;
268 +* Discharge voltage (min) – minimum discharging voltage, V;
269 +* Discharge current – maximum discharging current, А.
270 +
271 +=== ASTOM load bank (cycling) ===
272 +
273 +To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section:
274 +
275 +[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section:
276 +
277 +* Enable – a flag to enable communication with the bank;
278 +* Number of discharge cycles;
279 +* Minimum voltage of charged cells, V;
280 +* Voltage deviation of charged cells – minimum allowable deviation of the cells voltage at which battery states as charged, V;
281 +* Maximum discharge current, A;
282 +* Cell voltage to stop discharging, V;
283 +* SOC to be at the end of cycling – target SOC at the end of charge-discharge cycling, V;
284 +* Delay before starting discharging – a delay before transmitting command to the load to start discharging, millisecond;
285 +* Check the difference between the min and max cell voltage – a flag to enable check of difference between the minimum and maximum cell voltages to generate an error;
286 +* Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V;
287 +* Delay before setting the error – a delay before generating an error, second.
288 +
254 254  === HYG Class I-III truck ===
255 255  
256 256  The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE.
... ... @@ -298,7 +298,7 @@
298 298  
299 299  To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section:
300 300  
301 -[[image:1733753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
336 +[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]
302 302  
303 303  In this section:
304 304  
... ... @@ -308,6 +308,7 @@
308 308  * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur;
309 309  * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated;
310 310  * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated;
346 +* Do not set the "Combilift offline" error on the "Charger connected" signal;
311 311  * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %;
312 312  * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %;
313 313  * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift;
... ... @@ -415,13 +415,6 @@
415 415  After changing the settings, restart the BMS Mini device.
416 416  )))
417 417  
418 -=== ===
419 -
420 -(% class="box infomessage" %)
421 -(((
422 -
423 -)))
424 -
425 425  === ZiK truck ===
426 426  
427 427  To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section:
1740580440283-115.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +22.6 KB
Content
1740580507794-408.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +32.4 KB
Content
1740580581620-608.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +30.2 KB
Content
1740580850472-138.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.3 KB
Content