Changes for page 3.5 External equipment
Last modified by Admin on 2025/02/26 17:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -232,7 +232,7 @@ 232 232 After changing the settings, restart the BMS Mini device. 233 233 ))) 234 234 235 -=== Sunny Island inverter === 235 +=== SMA Sunny Island inverter === 236 236 237 237 To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → inverters → SMA Sunny Island inverter" section: 238 238 ... ... @@ -251,6 +251,41 @@ 251 251 252 252 When working with the Sunny Island inverter, the BMS Mini device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current. 253 253 254 +=== Pylontech inverter === 255 + 256 +To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section: 257 + 258 +[[image:1740580440283-115.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]] 259 + 260 +In this section: 261 + 262 +* Enable – a flag to enable communication with the inverter; 263 +* Type – invertor type: 264 +** Pylontech; 265 +** Solis; 266 +* Charge voltage, V – maximum charging voltage, V; 267 +* Charge current, А – maximum charging current, A; 268 +* Discharge voltage (min) – minimum discharging voltage, V; 269 +* Discharge current – maximum discharging current, А. 270 + 271 +=== ASTOM load bank (cycling) === 272 + 273 +To change the parameters of communication with a ASTOM load bank, select the "External equipment → Inverters and loads → ASTOM load bank (cycling)" section: 274 + 275 +[[image:1740580507794-408.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="190" width="800"]]In this section: 276 + 277 +* Enable – a flag to enable communication with the bank; 278 +* Number of discharge cycles; 279 +* Minimum voltage of charged cells, V; 280 +* Voltage deviation of charged cells – minimum allowable deviation of the cells voltage at which battery states as charged, V; 281 +* Maximum discharge current, A; 282 +* Cell voltage to stop discharging, V; 283 +* SOC to be at the end of cycling – target SOC at the end of charge-discharge cycling, V; 284 +* Delay before starting discharging – a delay before transmitting command to the load to start discharging, millisecond; 285 +* Check the difference between the min and max cell voltage – a flag to enable check of difference between the minimum and maximum cell voltages to generate an error; 286 +* Voltage difference – difference between the minimum and maximum cell voltages for error to be generated and cycling to be stopped, V; 287 +* Delay before setting the error – a delay before generating an error, second. 288 + 254 254 === HYG Class I-III truck === 255 255 256 256 The HYG Class I-III equipment is installed on the forklifts by the group of companies HYSTER-YALE. ... ... @@ -298,7 +298,7 @@ 298 298 299 299 To change communication parameters with a Combilift forklift, select the "External equipment → Trucks and Vehicles → Combilift truck" section: 300 300 301 -[[image:17 33753328056-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]336 +[[image:1740580581620-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]] 302 302 303 303 In this section: 304 304 ... ... @@ -308,6 +308,7 @@ 308 308 * Receive timeout – a timeout for receiving packets from the forklift (if no data is being received from the forklift during this time, the “Combilift offline“ flag is set), millisecond; at a value of 0 milliseconds, the "Combilift offline" error does not occur; 309 309 * Inhibit charging on the "Combilift offline" error – a flag to forbid charging if the "Combilift offline" error is generated; 310 310 * Inhibit discharging on "Combilift offline" error – a flag to forbid discharging if the "Combilift offline" error is generated; 346 +* Do not set the "Combilift offline" error on the "Charger connected" signal; 311 311 * SOC: Limited operation – a SOC level, at which the forklift goes into a state of limited functionality, %; 312 312 * SOC: Lift lockout – a SOC level, at which the forklift locks the lift, %; 313 313 * Send Heartbeat messages – a flag to enable generation of the Heartbeat messages to forklift; ... ... @@ -415,13 +415,6 @@ 415 415 After changing the settings, restart the BMS Mini device. 416 416 ))) 417 417 418 -=== === 419 - 420 -(% class="box infomessage" %) 421 -((( 422 - 423 -))) 424 - 425 425 === ZiK truck === 426 426 427 427 To change communication parameters with a ZiK truck, select the "External equipment → Trucks and Vehicles → ZiK truck" section: ... ... @@ -430,11 +430,10 @@ 430 430 431 431 In this section: 432 432 433 -* Settings: 434 -** Enable – a flag to enable communication with the ZiK truck; 435 -** Node ID – a ZiK identifier in the CANopen network; 436 -** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 437 -** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 462 +* Enable – a flag to enable communication with the ZiK truck; 463 +* Node ID – a ZiK identifier in the CANopen network; 464 +* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %; 465 +* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters. 438 438 439 439 The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds. 440 440 ... ... @@ -458,6 +458,34 @@ 458 458 * Receive vehicle messages – a flag to activate receiving vehicle messages; 459 459 * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network. 460 460 489 +=== Bender iso165C === 490 + 491 +To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section: 492 + 493 +[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 494 + 495 +In this section: 496 + 497 +* Enable – a flag to enable communication with the IMD; 498 +* Receive timeout – a timeout for receiving packets from the IMD, millisecond; 499 +* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning; 500 +* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm; 501 +* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm. 502 + 503 +=== BMS IMD === 504 + 505 +To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section: 506 + 507 +[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 508 + 509 +In this section: 510 + 511 +* Enable – a flag to enable communication with the IMD; 512 +* Node ID – a CANopen address of the BMS IMD device; 513 +* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings; 514 +* Threshold to detect insulation alarm, Ohm; 515 +* Threshold to detect insulation warning, Ohm. 516 + 461 461 === Main X === 462 462 463 463 The BMS Mini device can connect to BMS Main X strings controller.
- 1740580440283-115.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.6 KB - Content
- 1740580507794-408.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.4 KB - Content
- 1740580581620-608.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.2 KB - Content
- 1740580850472-138.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.3 KB - Content
- 1740580889560-625.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content