... ... @@ -459,10 +459,11 @@
459 459  
460 460  In this section:
461 461  
462 -* Enable – a flag to enable communication with the ZiK truck;
463 -* Node ID – a ZiK identifier in the CANopen network;
464 -* SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
465 -* Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
462 +* Settings:
463 +** Enable – a flag to enable communication with the ZiK truck;
464 +** Node ID – a ZiK identifier in the CANopen network;
465 +** SOC: Limited operation – a SOC level at which the truck goes to limited operation mode, %;
466 +** Send supercapacitor parameters – a flag to enable transmitting the supercapacitor parameters.
466 466  
467 467  The BMS with the identifier “Node ID” continuously transmits to the truck the control commands with a period of 100 milliseconds.
468 468  
... ... @@ -486,34 +486,6 @@
486 486  * Receive vehicle messages – a flag to activate receiving vehicle messages;
487 487  * First vehicle message ID – an identifier of the first message of the vehicle in the J1939 network.
488 488  
489 -=== Bender iso165C ===
490 -
491 -To change communication parameters with a Bender iso165C, select the "External equipment → IMD → Bender iso165C" section:
492 -
493 -[[image:1740580850472-138.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
494 -
495 -In this section:
496 -
497 -* Enable – a flag to enable communication with the IMD;
498 -* Receive timeout – a timeout for receiving packets from the IMD, millisecond;
499 -* Configure the IMD thresholds – a flag to enable the threshold values for generating insulation error and insulation warning;
500 -* Threshold to detect insulation error – threshold resistance value to generate the insulation error, Ohm;
501 -* Threshold to detect insulation warning – threshold resistance value to generate the insulation warning, Ohm.
502 -
503 -=== BMS IMD ===
504 -
505 -To change communication parameters with a BMS IMD, select the "External equipment → IMD → BMD IMD " section:
506 -
507 -[[image:1740580889560-625.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
508 -
509 -In this section:
510 -
511 -* Enable – a flag to enable communication with the IMD;
512 -* Node ID – a CANopen address of the BMS IMD device;
513 -* Configure the IMD thresholds – a flag to override the IMD warning and alarm settings;
514 -* Threshold to detect insulation alarm, Ohm;
515 -* Threshold to detect insulation warning, Ohm.
516 -
517 517  === Main X ===