... ... @@ -200,45 +200,43 @@
200 200  
201 201  [[image:1733753316203-976.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]]
202 202  
203 -In this section:
203 +В данном разделе:
204 204  
205 -* Enable – a flag to enable communication with the charger;
206 -* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
207 -* Charge voltage – maximum charging voltage, V;
208 -* Charge current – maximum charging current, A;
209 -* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
205 +* Enable – флаг разрешения работы с ЗУ Skytronic;
206 +* Receive timeout – таймаут получения пакетов от ЗУ (если в течение данного времени от ЗУ не поступает данных, то выставляется флаг потери связи с ЗУ), мс;
207 +* Charge voltage – максимальное напряжение заряда, В;
208 +* Charge current – максимальный ток заряда, А;
209 +* Set “Charger connected” signal if the charger is online – флаг формирования сигнала о подключении ЗУ в случае установления с ним информационного обмена.
210 210  
211 -Algorithm for working with the charger:
211 +Алгоритм работы с зарядным устройством: BMS выдаёт команду на заряд батареи при наличии сигнала «Allow charging» (см. [[Charge>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
212 212  
213 -The BMS sends a command to charge the battery if the "Allow charging" flag is set (see [[Charge>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]).
214 -
215 215  (% class="box infomessage" %)
216 216  (((
217 -After changing the settings, restart the BMS Mini device.
215 +После изменения настроек необходим перезапуск устройства BMS Mini.
218 218  )))
219 219  
220 220  === SMA Sunny Island inverter ===
221 221  
222 -To change the communication parameters with an SMA Sunny Island inverter, select the "External equipment → inverters → SMA Sunny Island inverter" section:
220 +Для изменения параметров связи с инверторами Sunny Island компании SMA необходимо выбрать раздел «External equipment → Inverters → SMA Sunny Island inverter»:
223 223  
224 224  [[image:1733753328053-956.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]]
225 225  
226 -In this section:
224 +В данном разделе:
227 227  
228 -* Enable – a flag to enable communication with the inverter;
229 -* Receive timeout – a timeout for receiving packets from the inverter (if no data is being received from the inverter during this time, the connection loss flag is set), millisecond;
230 -* Output period – a period of sending commands to the inverter, millisecond;
231 -* Charge voltage, V maximum charging voltage, V;
232 -* Charge current, А maximum charging current, A;
233 -* Discharge voltage (min) minimum discharging voltage, V;
234 -* Discharge current – maximum discharging current, А;
235 -* Invert current – a flag to inverse current sent to the inverter;
226 +* Enable – флаг разрешения работы с инвертором;
227 +* Receive timeout – таймаут диспетчеризации пакетов от инвертора (если в течение данного времени от инвертора не поступает данных, то выставляется флаг потери связи с инвертором), мс;
228 +* Output period – период отправки команд инвертору, мс;
229 +* Charging voltage – максимальное напряжение заряда, В;
230 +* Charging current – максимальный ток заряда, А;
231 +* Discharging voltage – максимальное напряжение разряда, В;
232 +* Discharging current – максимальный ток разряда, А;
233 +* Invert current – флаг инверсии тока, передаваемого инвертору.
236 236  
237 -When working with the Sunny Island inverter, the BMS Mini device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current.
235 +При работе с инвертором Sunny Island устройство BMS Mini непрерывно с периодом Output period отправляют пакеты со значениями напряжения и тока заряда/разряда: Charging voltage, Charging current, Discharging voltage, Discharging current.
238 238  
239 239  === Pylontech inverter ===
240 240  
241 -To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
239 +Для изменения параметров связи с инвертором Pylontech необходимо выбрать раздел «External equipment → Inverters and loads → Pylontech inverter»:
242 242  
243 243  [[image:1740580440283-115.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]]
244 244