576 576  The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
577 577  
578 578  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
579 +
580 +=== General error ===
581 +
582 +To change the general error parameters, select the "Protections → Critical error" section:
583 +
584 +[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]
585 +
586 +In this section:
587 +
588 +* Enable – a flag to enable the protection;
589 +* Delay before setting the error, millisecond;
590 +* Delay before clearing the error, second;
591 +* Lock – a flag to block the error until the device is restarted;
592 +* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors.
593 +
594 +The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
595 +
596 +The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time.
597 +
598 +The state of the “General error” can be assigned to a discrete output or to a power switch.