... ... @@ -410,7 +410,7 @@
410 410  
411 411  To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section:
412 412  
413 -[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]]
413 +[[image:1733748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]
414 414  
415 415  In this section:
416 416  
... ... @@ -420,6 +420,7 @@
420 420  * Delay before setting the error, millisecond;
421 421  * Delay before clearing the error, second;
422 422  * Lock – a flag to block the error until the device is restarted.
423 +* Number of cycles – a number of the charging contactor switchings made during battery operation.
423 423  
424 424  If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated.
425 425  
... ... @@ -545,15 +545,11 @@
545 545  
546 546  To change the insulation monitoring parameters, select the "Protections → Insulation" section:
547 547  
548 -[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]]
549 +[[image:1733748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
549 549  
550 550  In this section:
551 551  
552 552  * Enable – a flag to enable the protection;
553 -* Checking algorithm – isolation checking mode:
554 -** Always on – check is always performed;
555 -** On charging – check is performed only if “Charger connected” or “Charge request” is set;
556 -** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared;
557 557  * Delay before setting the error, second;
558 558  * Delay before clearing the error, second;
559 559  * Lock – a flag to block the error until the device is restarted.