... ... @@ -573,21 +573,26 @@
573 573  * Delay before clearing the error, second;
574 574  * Lock – a flag to block the error until the device is restarted.
575 575  
576 -The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
577 577  
578 -* “Battery cover error”;
579 -* “Cell monitor offline”;
580 -* “Cell count error”;
581 -* “ADC error”;
582 -* “Current sensor error”;
583 -* “Shunt offline”;
584 -* “Shunt error”;
585 -* “No temp. sensors”;
586 -* “Temp. sensor is shorted”;
587 -* “Settings error”;
588 -* “WDT reset”;
589 -* “Stuck contactor”;
590 -* “Contactor feedback error”;
591 -* “Insulation fault”.
592 -
593 593  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
579 +
580 +=== General error ===
581 +
582 +To change the general error parameters, select the "Protections → Critical error" section:
583 +
584 +[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]
585 +
586 +In this section:
587 +
588 +* Enable – a flag to enable the protection;
589 +* Delay before setting the error, millisecond;
590 +* Delay before clearing the error, second;
591 +* Lock – a flag to block the error until the device is restarted;
592 +* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors.
593 +
594 +The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
595 +
596 +The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time.
597 +
598 +The state of the “General error” can be assigned to a discrete output or to a power switch.