Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -573,21 +573,6 @@ 573 573 * Delay before clearing the error, second; 574 574 * Lock – a flag to block the error until the device is restarted. 575 575 576 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 577 577 578 -* “Battery cover error”; 579 -* “Cell monitor offline”; 580 -* “Cell count error”; 581 -* “ADC error”; 582 -* “Current sensor error”; 583 -* “Shunt offline”; 584 -* “Shunt error”; 585 -* “No temp. sensors”; 586 -* “Temp. sensor is shorted”; 587 -* “Settings error”; 588 -* “WDT reset”; 589 -* “Stuck contactor”; 590 -* “Contactor feedback error”; 591 -* “Insulation fault”. 592 - 593 593 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.