... ... @@ -573,21 +573,6 @@
573 573  * Delay before clearing the error, second;
574 574  * Lock – a flag to block the error until the device is restarted.
575 575  
576 -The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
577 577  
578 -* “Battery cover error”;
579 -* “Cell monitor offline”;
580 -* “Cell count error”;
581 -* “ADC error”;
582 -* “Current sensor error”;
583 -* “Shunt offline”;
584 -* “Shunt error”;
585 -* “No temp. sensors”;
586 -* “Temp. sensor is shorted”;
587 -* “Settings error”;
588 -* “WDT reset”;
589 -* “Stuck contactor”;
590 -* “Contactor feedback error”;
591 -* “Insulation fault”.
592 -
593 593  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.