Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -545,11 +545,15 @@ 545 545 546 546 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 547 547 548 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]548 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 549 549 550 550 In this section: 551 551 552 552 * Enable – a flag to enable the protection; 553 +* Checking algorithm – isolation checking mode: 554 +** Always on – check is always performed; 555 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 556 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 553 553 * Delay before setting the error, second; 554 554 * Delay before clearing the error, second; 555 555 * Lock – a flag to block the error until the device is restarted. ... ... @@ -569,21 +569,6 @@ 569 569 * Delay before clearing the error, second; 570 570 * Lock – a flag to block the error until the device is restarted. 571 571 572 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 573 573 574 -* “Battery cover error”; 575 -* “Cell monitor offline”; 576 -* “Cell count error”; 577 -* “ADC error”; 578 -* “Current sensor error”; 579 -* “Shunt offline”; 580 -* “Shunt error”; 581 -* “No temp. sensors”; 582 -* “Temp. sensor is shorted”; 583 -* “Settings error”; 584 -* “WDT reset”; 585 -* “Stuck contactor”; 586 -* “Contactor feedback error”; 587 -* “Insulation fault”. 588 - 589 589 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content