Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:23

From version 6.5
edited by Admin
on 2025/02/26 12:06
Change comment: There is no comment for this version
To version 8.2
edited by Admin
on 2025/02/26 12:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -410,7 +410,7 @@
410 410  
411 411  To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section:
412 412  
413 -[[image:1733748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]
413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]]
414 414  
415 415  In this section:
416 416  
... ... @@ -420,7 +420,6 @@
420 420  * Delay before setting the error, millisecond;
421 421  * Delay before clearing the error, second;
422 422  * Lock – a flag to block the error until the device is restarted.
423 -* Number of cycles – a number of the charging contactor switchings made during battery operation.
424 424  
425 425  If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated.
426 426  
... ... @@ -546,11 +546,15 @@
546 546  
547 547  To change the insulation monitoring parameters, select the "Protections → Insulation" section:
548 548  
549 -[[image:1733748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
548 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]]
550 550  
551 551  In this section:
552 552  
553 553  * Enable – a flag to enable the protection;
553 +* Checking algorithm – isolation checking mode:
554 +** Always on – check is always performed;
555 +** On charging – check is performed only if “Charger connected” or “Charge request” is set;
556 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared;
554 554  * Delay before setting the error, second;
555 555  * Delay before clearing the error, second;
556 556  * Lock – a flag to block the error until the device is restarted.
1740571600741-802.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.6 KB
Content
1740573733492-485.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content