Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -410,7 +410,7 @@ 410 410 411 411 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 412 412 413 -[[image:17 33748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]] 414 414 415 415 In this section: 416 416 ... ... @@ -420,7 +420,6 @@ 420 420 * Delay before setting the error, millisecond; 421 421 * Delay before clearing the error, second; 422 422 * Lock – a flag to block the error until the device is restarted. 423 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 424 424 425 425 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 426 426 ... ... @@ -521,6 +521,11 @@ 521 521 522 522 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 523 523 523 +(% class="box warningmessage" %) 524 +((( 525 +If there is the "Stuck contactor" error, the **“Critical error” **is generated. 526 +))) 527 + 524 524 === Contactor feedback === 525 525 526 526 The BMS Mini device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to corresponding contactor feedback pin on X1 header. ... ... @@ -540,6 +540,11 @@ 540 540 541 541 * a command for charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 542 542 547 +(% class="box warningmessage" %) 548 +((( 549 +If there is the "Contactor feedback" error, the **“Critical error” **is generated. 550 +))) 551 + 543 543 === Insulation === 544 544 545 545 The BMS Mini device can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. ... ... @@ -546,11 +546,15 @@ 546 546 547 547 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 548 548 549 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]558 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 550 550 551 551 In this section: 552 552 553 553 * Enable – a flag to enable the protection; 563 +* Checking algorithm – isolation checking mode: 564 +** Always on – check is always performed; 565 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 566 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 554 554 * Delay before setting the error, second; 555 555 * Delay before clearing the error, second; 556 556 * Lock – a flag to block the error until the device is restarted. ... ... @@ -557,6 +557,11 @@ 557 557 558 558 Error is set if corresponding discrete input is set up and it receives logical zero. 559 559 573 +(% class="box warningmessage" %) 574 +((( 575 +If there is the "Insulation" error, the **“Critical error” **is generated. 576 +))) 577 + 560 560 === Critical error === 561 561 562 562 To change the critical error parameters, select the "Protections → Critical error" section: ... ... @@ -570,21 +570,29 @@ 570 570 * Delay before clearing the error, second; 571 571 * Lock – a flag to block the error until the device is restarted. 572 572 573 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:591 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 574 574 575 -* “Battery cover error”; 576 -* “Cell monitor offline”; 577 -* “Cell count error”; 578 -* “ADC error”; 579 -* “Current sensor error”; 580 -* “Shunt offline”; 581 -* “Shunt error”; 582 -* “No temp. sensors”; 583 -* “Temp. sensor is shorted”; 584 -* “Settings error”; 585 -* “WDT reset”; 586 -* “Stuck contactor”; 587 -* “Contactor feedback error”; 588 -* “Insulation fault”. 589 - 590 590 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 594 + 595 +=== General error === 596 + 597 +To change the general error parameters, select the "Protections → Critical error" section: 598 + 599 +[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 600 + 601 +In this section: 602 + 603 +* Enable – a flag to enable the protection; 604 +* Delay before setting the error, millisecond; 605 +* Delay before clearing the error, second; 606 +* Lock – a flag to block the error until the device is restarted; 607 +* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 608 + 609 +The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 610 + 611 +The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 612 + 613 +(% class="box warningmessage" %) 614 +((( 615 +The state of the “General error” can be assigned to a discrete output or to a power switch. 616 +)))
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content