Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -393,7 +393,6 @@ 393 393 * Delay before setting the error, millisecond; 394 394 * Delay before clearing the error, second; 395 395 * Lock – a flag to block the error until the device is restarted. 396 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 397 397 398 398 If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated. 399 399 ... ... @@ -411,7 +411,7 @@ 411 411 412 412 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 413 413 414 -[[image:17 33748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]] 415 415 416 416 In this section: 417 417 ... ... @@ -421,7 +421,6 @@ 421 421 * Delay before setting the error, millisecond; 422 422 * Delay before clearing the error, second; 423 423 * Lock – a flag to block the error until the device is restarted. 424 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 425 425 426 426 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 427 427 ... ... @@ -547,11 +547,15 @@ 547 547 548 548 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 549 549 550 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]548 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 551 551 552 552 In this section: 553 553 554 554 * Enable – a flag to enable the protection; 553 +* Checking algorithm – isolation checking mode: 554 +** Always on – check is always performed; 555 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 556 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 555 555 * Delay before setting the error, second; 556 556 * Delay before clearing the error, second; 557 557 * Lock – a flag to block the error until the device is restarted.
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content