Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:23

From version 6.4
edited by Admin
on 2025/02/26 12:04
Change comment: There is no comment for this version
To version 6.2
edited by Admin
on 2025/02/26 12:03
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -117,7 +117,7 @@
117 117  
118 118  To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section:
119 119  
120 -[[image:1740571383842-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="800"]]
120 +[[image:1740571383842-536.png]]
121 121  
122 122  In this section:
123 123  
... ... @@ -124,9 +124,9 @@
124 124  * Enable – a flag to enable the protection;
125 125  * Maximum cell voltage, V;
126 126  * Tolerant cell voltage, V;
127 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
128 128  * Delay before setting the error, millisecond;
129 129  * Delay before clearing the error, second;
129 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
130 130  * Lock – a flag to block the error until the device is restarted.
131 131  
132 132  As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.