Changes for page 3.4 Protections
Last modified by Admin on 2025/11/10 11:45
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -96,7 +96,7 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Minimum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 -* Check the open circuit voltage instead of the actual voltage – a flag to e nablethecheckofvoltagecorrectiondue to current and cell resistance;99 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage instead of measured value; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 102 102 * Lock – a flag to block the error until the device is restarted. ... ... @@ -124,7 +124,7 @@ 124 124 * Enable – a flag to enable the protection; 125 125 * Maximum cell voltage, V; 126 126 * Tolerant cell voltage, V; 127 -* Check the open circuit voltage instead of the actual voltage – a flag to e nablethecheckofvoltagecorrectiondue to current and cell resistance;127 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage instead of measured value; 128 128 * Delay before setting the error, millisecond; 129 129 * Delay before clearing the error, second; 130 130 * Lock – a flag to block the error until the device is restarted. ... ... @@ -139,6 +139,33 @@ 139 139 140 140 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 141 141 142 +=== Cell imbalance === 143 + 144 +The BMS Mini S device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold. 145 + 146 +To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section: 147 + 148 +[[image:1762772978976-565.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]] 149 + 150 +In this section: 151 + 152 +* Enable – a flag to enable the protection; 153 +* Maximum cell imbalance, V; 154 +* Tolerant cell imbalance, V; 155 +* Delay before setting the error, millisecond; 156 +* Delay before clearing the error, second; 157 +* Lock – a flag to block the error until the device is restarted. 158 + 159 +As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 160 + 161 +Error generation conditions: 162 + 163 +* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time. 164 + 165 +Conditions for removing the error: 166 + 167 +* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time. 168 + 142 142 === Low temperature === 143 143 144 144 The BMS Mini device implements battery protection from too low temperature. ... ... @@ -282,6 +282,35 @@ 282 282 If there is the "Cell count error", the **“Critical error” **is generated. 283 283 ))) 284 284 312 +=== Temperature sensor count === 313 + 314 +To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section: 315 + 316 +[[image:1762773073782-768.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]] 317 + 318 +In this section: 319 + 320 +* Enable – a flag to enable the protection; 321 +* Number of cells – a number of temperature sensors connected to the BMS; 322 +* Delay before setting the error, millisecond; 323 +* Delay before clearing the error, second; 324 +* Lock – a flag to block the error until the device is restarted. 325 + 326 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 327 + 328 +Error generation conditions: 329 + 330 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 331 + 332 +Conditions for removing the error: 333 + 334 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 335 + 336 +(% class="box warningmessage" %) 337 +((( 338 +If there is the "T-sensor count error", the **“Critical error” **is generated**.** 339 +))) 340 + 285 285 === Short circuit === 286 286 287 287 The BMS Mini device implements a protection of power circuits (contactors, power wires) against overheating caused by the flow of high current for a long time. ... ... @@ -377,6 +377,24 @@ 377 377 If there is the “Current sensor error”, the **“Critical error” **is generated. 378 378 ))) 379 379 436 +=== MOSFET === 437 + 438 +BMS Mini S device checks the status of MOSFET switches that are used to control the contactors. To change the parameters of the MOSFET switch protection, select the "Protections → MOSFET " section: 439 + 440 +[[image:1762773566548-852.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]] 441 + 442 +In this section: 443 + 444 +* Delay before clearing the error, second; 445 +* Lock – a flag to block the error until the device is restarted. 446 + 447 +The “MOSFET error” occurs when the device detects a shortage in contactor coil control circuit or an overheating of the MOSFET switch. Error is removed when the temperature of MOSFET switch is normal during “Delay before clearing the error” time. 448 + 449 +(% class="box warningmessage" %) 450 +((( 451 +If there is the "MOSFET error", the **“Critical error” **is generated. 452 +))) 453 + 380 380 === Charge contactor cycles === 381 381 382 382 The BMS Mini device protects the charging contactor against frequent switching. ... ... @@ -393,7 +393,6 @@ 393 393 * Delay before setting the error, millisecond; 394 394 * Delay before clearing the error, second; 395 395 * Lock – a flag to block the error until the device is restarted. 396 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 397 397 398 398 If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated. 399 399 ... ... @@ -405,13 +405,13 @@ 405 405 406 406 * the “Delay before clearing the error” time has passed since the error was generated. 407 407 408 -=== Discharge contactor cycles protection===481 +=== Discharge contactor cycles === 409 409 410 410 The BMS Mini device protects the discharging contactor against frequent switching. 411 411 412 412 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 413 413 414 -[[image:17 33748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]487 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]] 415 415 416 416 In this section: 417 417 ... ... @@ -421,7 +421,6 @@ 421 421 * Delay before setting the error, millisecond; 422 422 * Delay before clearing the error, second; 423 423 * Lock – a flag to block the error until the device is restarted. 424 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 425 425 426 426 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 427 427 ... ... @@ -522,6 +522,11 @@ 522 522 523 523 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 524 524 597 +(% class="box warningmessage" %) 598 +((( 599 +If there is the "Stuck contactor" error, the **“Critical error” **is generated. 600 +))) 601 + 525 525 === Contactor feedback === 526 526 527 527 The BMS Mini device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to corresponding contactor feedback pin on X1 header. ... ... @@ -541,6 +541,11 @@ 541 541 542 542 * a command for charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 543 543 621 +(% class="box warningmessage" %) 622 +((( 623 +If there is the "Contactor feedback" error, the **“Critical error” **is generated. 624 +))) 625 + 544 544 === Insulation === 545 545 546 546 The BMS Mini device can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. ... ... @@ -547,11 +547,15 @@ 547 547 548 548 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 549 549 550 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]632 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 551 551 552 552 In this section: 553 553 554 554 * Enable – a flag to enable the protection; 637 +* Checking algorithm – isolation checking mode: 638 +** Always on – check is always performed; 639 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 640 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 555 555 * Delay before setting the error, second; 556 556 * Delay before clearing the error, second; 557 557 * Lock – a flag to block the error until the device is restarted. ... ... @@ -558,6 +558,11 @@ 558 558 559 559 Error is set if corresponding discrete input is set up and it receives logical zero. 560 560 647 +(% class="box warningmessage" %) 648 +((( 649 +If there is the "Insulation" error, the **“Critical error” **is generated. 650 +))) 651 + 561 561 === Critical error === 562 562 563 563 To change the critical error parameters, select the "Protections → Critical error" section: ... ... @@ -571,21 +571,29 @@ 571 571 * Delay before clearing the error, second; 572 572 * Lock – a flag to block the error until the device is restarted. 573 573 574 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:665 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 575 575 576 -* “Battery cover error”; 577 -* “Cell monitor offline”; 578 -* “Cell count error”; 579 -* “ADC error”; 580 -* “Current sensor error”; 581 -* “Shunt offline”; 582 -* “Shunt error”; 583 -* “No temp. sensors”; 584 -* “Temp. sensor is shorted”; 585 -* “Settings error”; 586 -* “WDT reset”; 587 -* “Stuck contactor”; 588 -* “Contactor feedback error”; 589 -* “Insulation fault”. 590 - 591 591 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 668 + 669 +=== General error === 670 + 671 +To change the general error parameters, select the "Protections → Critical error" section: 672 + 673 +[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 674 + 675 +In this section: 676 + 677 +* Enable – a flag to enable the protection; 678 +* Delay before setting the error, millisecond; 679 +* Delay before clearing the error, second; 680 +* Lock – a flag to block the error until the device is restarted; 681 +* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 682 + 683 +The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 684 + 685 +The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 686 + 687 +(% class="box warningmessage" %) 688 +((( 689 +The state of the “General error” can be assigned to a discrete output or to a power switch. 690 +)))
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content
- 1762772949184-209.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.0 KB - Content
- 1762772978976-565.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.0 KB - Content
- 1762773073782-768.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.6 KB - Content
- 1762773136224-775.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.6 KB - Content
- 1762773285560-458.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1762773566548-852.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1762775067035-203.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.4 KB - Content