Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -96,7 +96,7 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Minimum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 -* Check the open circuit voltage instead of the actual voltage – a flag to e nablethecheckofvoltagecorrectiondue to current and cell resistance;99 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 102 102 * Lock – a flag to block the error until the device is restarted. ... ... @@ -124,7 +124,7 @@ 124 124 * Enable – a flag to enable the protection; 125 125 * Maximum cell voltage, V; 126 126 * Tolerant cell voltage, V; 127 -* Check the open circuit voltage instead of the actual voltage – a flag to e nablethecheckofvoltagecorrectiondue to current and cell resistance;127 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 128 128 * Delay before setting the error, millisecond; 129 129 * Delay before clearing the error, second; 130 130 * Lock – a flag to block the error until the device is restarted. ... ... @@ -393,7 +393,6 @@ 393 393 * Delay before setting the error, millisecond; 394 394 * Delay before clearing the error, second; 395 395 * Lock – a flag to block the error until the device is restarted. 396 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 397 397 398 398 If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated. 399 399 ... ... @@ -411,7 +411,7 @@ 411 411 412 412 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 413 413 414 -[[image:17 33748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]] 415 415 416 416 In this section: 417 417 ... ... @@ -421,7 +421,6 @@ 421 421 * Delay before setting the error, millisecond; 422 422 * Delay before clearing the error, second; 423 423 * Lock – a flag to block the error until the device is restarted. 424 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 425 425 426 426 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 427 427 ... ... @@ -522,6 +522,11 @@ 522 522 523 523 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 524 524 523 +(% class="box warningmessage" %) 524 +((( 525 +If there is the "Stuck contactor" error, the **“Critical error” **is generated. 526 +))) 527 + 525 525 === Contactor feedback === 526 526 527 527 The BMS Mini device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to corresponding contactor feedback pin on X1 header. ... ... @@ -541,6 +541,11 @@ 541 541 542 542 * a command for charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 543 543 547 +(% class="box warningmessage" %) 548 +((( 549 +If there is the "Contactor feedback" error, the **“Critical error” **is generated. 550 +))) 551 + 544 544 === Insulation === 545 545 546 546 The BMS Mini device can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. ... ... @@ -547,11 +547,15 @@ 547 547 548 548 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 549 549 550 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]558 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 551 551 552 552 In this section: 553 553 554 554 * Enable – a flag to enable the protection; 563 +* Checking algorithm – isolation checking mode: 564 +** Always on – check is always performed; 565 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 566 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 555 555 * Delay before setting the error, second; 556 556 * Delay before clearing the error, second; 557 557 * Lock – a flag to block the error until the device is restarted. ... ... @@ -558,6 +558,11 @@ 558 558 559 559 Error is set if corresponding discrete input is set up and it receives logical zero. 560 560 573 +(% class="box warningmessage" %) 574 +((( 575 +If there is the "Insulation" error, the **“Critical error” **is generated. 576 +))) 577 + 561 561 === Critical error === 562 562 563 563 To change the critical error parameters, select the "Protections → Critical error" section: ... ... @@ -571,21 +571,29 @@ 571 571 * Delay before clearing the error, second; 572 572 * Lock – a flag to block the error until the device is restarted. 573 573 574 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:591 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 575 575 576 -* “Battery cover error”; 577 -* “Cell monitor offline”; 578 -* “Cell count error”; 579 -* “ADC error”; 580 -* “Current sensor error”; 581 -* “Shunt offline”; 582 -* “Shunt error”; 583 -* “No temp. sensors”; 584 -* “Temp. sensor is shorted”; 585 -* “Settings error”; 586 -* “WDT reset”; 587 -* “Stuck contactor”; 588 -* “Contactor feedback error”; 589 -* “Insulation fault”. 590 - 591 591 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 594 + 595 +=== General error === 596 + 597 +To change the general error parameters, select the "Protections → Critical error" section: 598 + 599 +[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 600 + 601 +In this section: 602 + 603 +* Enable – a flag to enable the protection; 604 +* Delay before setting the error, millisecond; 605 +* Delay before clearing the error, second; 606 +* Lock – a flag to block the error until the device is restarted; 607 +* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 608 + 609 +The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 610 + 611 +The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 612 + 613 +(% class="box warningmessage" %) 614 +((( 615 +The state of the “General error” can be assigned to a discrete output or to a power switch. 616 +)))
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content