Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:23

From version 6.3
edited by Admin
on 2025/02/26 12:03
Change comment: There is no comment for this version
To version 7.1
edited by Admin
on 2025/02/26 12:06
Change comment: Загрузить новое вложение 1740571600741-802.png

Summary

Details

Page properties
Content
... ... @@ -127,7 +127,6 @@
127 127  * Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
128 128  * Delay before setting the error, millisecond;
129 129  * Delay before clearing the error, second;
130 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
131 131  * Lock – a flag to block the error until the device is restarted.
132 132  
133 133  As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
... ... @@ -394,7 +394,6 @@
394 394  * Delay before setting the error, millisecond;
395 395  * Delay before clearing the error, second;
396 396  * Lock – a flag to block the error until the device is restarted.
397 -* Number of cycles – a number of the charging contactor switchings made during battery operation.
398 398  
399 399  If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated.
400 400  
1740571600741-802.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.6 KB
Content