Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -71,18 +71,8 @@ 71 71 72 72 To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section: 73 73 74 -[[image:1740571296344-411.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="151" width="800"]]74 +[[image:1740571296344-411.png]] 75 75 76 -In this section: 77 - 78 -* Enable – a flag to enable the protection; 79 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 80 -* Region 1: Current difference – a value of maximum absolute current difference, A; 81 -* Region 2: Current difference – a value of maximum relative current excess, A; 82 -* Delay before setting the error, millisecond; 83 -* Delay before clearing the error, second; 84 -* Lock – a flag to block the error until the device is restarted. 85 - 86 86 === Undervoltage === 87 87 88 88 The BMS Mini device implements battery protection from too low voltage on the cells. ... ... @@ -89,7 +89,7 @@ 89 89 90 90 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 91 91 92 -[[image:1740 571345293-460.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]82 +[[image:1733748033237-837.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 93 93 94 94 In this section: 95 95 ... ... @@ -96,7 +96,6 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Minimum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 102 102 * Lock – a flag to block the error until the device is restarted. ... ... @@ -117,7 +117,7 @@ 117 117 118 118 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 119 119 120 -[[image:1740 571383842-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="800"]]109 +[[image:1733748033238-995.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 121 121 122 122 In this section: 123 123 ... ... @@ -124,7 +124,6 @@ 124 124 * Enable – a flag to enable the protection; 125 125 * Maximum cell voltage, V; 126 126 * Tolerant cell voltage, V; 127 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 128 128 * Delay before setting the error, millisecond; 129 129 * Delay before clearing the error, second; 130 130 * Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
- 1740571383842-536.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content