Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -127,7 +127,6 @@ 127 127 * Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 128 128 * Delay before setting the error, millisecond; 129 129 * Delay before clearing the error, second; 130 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 131 131 * Lock – a flag to block the error until the device is restarted. 132 132 133 133 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -394,7 +394,6 @@ 394 394 * Delay before setting the error, millisecond; 395 395 * Delay before clearing the error, second; 396 396 * Lock – a flag to block the error until the device is restarted. 397 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 398 398 399 399 If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated. 400 400 ... ... @@ -412,7 +412,7 @@ 412 412 413 413 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 414 414 415 -[[image:17 33748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]] 416 416 417 417 In this section: 418 418 ... ... @@ -422,7 +422,6 @@ 422 422 * Delay before setting the error, millisecond; 423 423 * Delay before clearing the error, second; 424 424 * Lock – a flag to block the error until the device is restarted. 425 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 426 426 427 427 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 428 428 ... ... @@ -548,11 +548,15 @@ 548 548 549 549 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 550 550 551 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]548 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 552 552 553 553 In this section: 554 554 555 555 * Enable – a flag to enable the protection; 553 +* Checking algorithm – isolation checking mode: 554 +** Always on – check is always performed; 555 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 556 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 556 556 * Delay before setting the error, second; 557 557 * Delay before clearing the error, second; 558 558 * Lock – a flag to block the error until the device is restarted. ... ... @@ -572,21 +572,6 @@ 572 572 * Delay before clearing the error, second; 573 573 * Lock – a flag to block the error until the device is restarted. 574 574 575 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 576 576 577 -* “Battery cover error”; 578 -* “Cell monitor offline”; 579 -* “Cell count error”; 580 -* “ADC error”; 581 -* “Current sensor error”; 582 -* “Shunt offline”; 583 -* “Shunt error”; 584 -* “No temp. sensors”; 585 -* “Temp. sensor is shorted”; 586 -* “Settings error”; 587 -* “WDT reset”; 588 -* “Stuck contactor”; 589 -* “Contactor feedback error”; 590 -* “Insulation fault”. 591 - 592 592 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content