Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:23

From version 6.2
edited by Admin
on 2025/02/26 12:03
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/02/26 12:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -117,7 +117,7 @@
117 117  
118 118  To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section:
119 119  
120 -[[image:1740571383842-536.png]]
120 +[[image:1740571383842-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="800"]]
121 121  
122 122  In this section:
123 123  
... ... @@ -124,9 +124,9 @@
124 124  * Enable – a flag to enable the protection;
125 125  * Maximum cell voltage, V;
126 126  * Tolerant cell voltage, V;
127 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
127 127  * Delay before setting the error, millisecond;
128 128  * Delay before clearing the error, second;
129 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
130 130  * Lock – a flag to block the error until the device is restarted.
131 131  
132 132  As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
... ... @@ -393,7 +393,6 @@
393 393  * Delay before setting the error, millisecond;
394 394  * Delay before clearing the error, second;
395 395  * Lock – a flag to block the error until the device is restarted.
396 -* Number of cycles – a number of the charging contactor switchings made during battery operation.
397 397  
398 398  If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated.
399 399  
... ... @@ -411,7 +411,7 @@
411 411  
412 412  To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section:
413 413  
414 -[[image:1733748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]
413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]]
415 415  
416 416  In this section:
417 417  
... ... @@ -421,7 +421,6 @@
421 421  * Delay before setting the error, millisecond;
422 422  * Delay before clearing the error, second;
423 423  * Lock – a flag to block the error until the device is restarted.
424 -* Number of cycles – a number of the charging contactor switchings made during battery operation.
425 425  
426 426  If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated.
427 427  
... ... @@ -547,11 +547,15 @@
547 547  
548 548  To change the insulation monitoring parameters, select the "Protections → Insulation" section:
549 549  
550 -[[image:1733748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
548 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]]
551 551  
552 552  In this section:
553 553  
554 554  * Enable – a flag to enable the protection;
553 +* Checking algorithm – isolation checking mode:
554 +** Always on – check is always performed;
555 +** On charging – check is performed only if “Charger connected” or “Charge request” is set;
556 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared;
555 555  * Delay before setting the error, second;
556 556  * Delay before clearing the error, second;
557 557  * Lock – a flag to block the error until the device is restarted.
... ... @@ -571,21 +571,26 @@
571 571  * Delay before clearing the error, second;
572 572  * Lock – a flag to block the error until the device is restarted.
573 573  
574 -The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
575 575  
576 -* “Battery cover error”;
577 -* “Cell monitor offline”;
578 -* “Cell count error”;
579 -* “ADC error”;
580 -* “Current sensor error”;
581 -* “Shunt offline”;
582 -* “Shunt error”;
583 -* “No temp. sensors”;
584 -* “Temp. sensor is shorted”;
585 -* “Settings error”;
586 -* “WDT reset”;
587 -* “Stuck contactor”;
588 -* “Contactor feedback error”;
589 -* “Insulation fault”.
590 -
591 591  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
579 +
580 +=== General error ===
581 +
582 +To change the general error parameters, select the "Protections → Critical error" section:
583 +
584 +[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]
585 +
586 +In this section:
587 +
588 +* Enable – a flag to enable the protection;
589 +* Delay before setting the error, millisecond;
590 +* Delay before clearing the error, second;
591 +* Lock – a flag to block the error until the device is restarted;
592 +* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors.
593 +
594 +The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
595 +
596 +The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time.
597 +
598 +The state of the “General error” can be assigned to a discrete output or to a power switch.
1740571600741-802.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.6 KB
Content
1740573733492-485.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
1740573914327-561.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.6 KB
Content