Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -117,7 +117,7 @@ 117 117 118 118 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 119 119 120 -[[image:1740571383842-536.png]] 120 +[[image:1740571383842-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="800"]] 121 121 122 122 In this section: 123 123 ... ... @@ -124,9 +124,9 @@ 124 124 * Enable – a flag to enable the protection; 125 125 * Maximum cell voltage, V; 126 126 * Tolerant cell voltage, V; 127 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 127 127 * Delay before setting the error, millisecond; 128 128 * Delay before clearing the error, second; 129 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 130 130 * Lock – a flag to block the error until the device is restarted. 131 131 132 132 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -393,7 +393,6 @@ 393 393 * Delay before setting the error, millisecond; 394 394 * Delay before clearing the error, second; 395 395 * Lock – a flag to block the error until the device is restarted. 396 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 397 397 398 398 If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated. 399 399 ... ... @@ -411,7 +411,7 @@ 411 411 412 412 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 413 413 414 -[[image:17 33748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]] 415 415 416 416 In this section: 417 417 ... ... @@ -421,7 +421,6 @@ 421 421 * Delay before setting the error, millisecond; 422 422 * Delay before clearing the error, second; 423 423 * Lock – a flag to block the error until the device is restarted. 424 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 425 425 426 426 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 427 427 ... ... @@ -547,11 +547,15 @@ 547 547 548 548 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 549 549 550 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]548 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 551 551 552 552 In this section: 553 553 554 554 * Enable – a flag to enable the protection; 553 +* Checking algorithm – isolation checking mode: 554 +** Always on – check is always performed; 555 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 556 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 555 555 * Delay before setting the error, second; 556 556 * Delay before clearing the error, second; 557 557 * Lock – a flag to block the error until the device is restarted. ... ... @@ -571,21 +571,6 @@ 571 571 * Delay before clearing the error, second; 572 572 * Lock – a flag to block the error until the device is restarted. 573 573 574 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 575 575 576 -* “Battery cover error”; 577 -* “Cell monitor offline”; 578 -* “Cell count error”; 579 -* “ADC error”; 580 -* “Current sensor error”; 581 -* “Shunt offline”; 582 -* “Shunt error”; 583 -* “No temp. sensors”; 584 -* “Temp. sensor is shorted”; 585 -* “Settings error”; 586 -* “WDT reset”; 587 -* “Stuck contactor”; 588 -* “Contactor feedback error”; 589 -* “Insulation fault”. 590 - 591 591 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content