... ... @@ -43,46 +43,11 @@ 43 43 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 44 44 * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 45 45 46 -=== Charge current limit === 46 +(% class="box infomessage" %) 47 +((( 48 +If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 49 +))) 47 47 48 -The BMS Mini device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 49 - 50 -Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 51 - 52 -To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section: 53 - 54 -[[image:1740571132019-848.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="143" width="800"]] 55 - 56 -In this section: 57 - 58 -* Enable – a flag to enable the protection; 59 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 60 -* Region 1: Current difference – a value of maximum absolute current difference, A; 61 -* Region 2: Current difference – a value of maximum relative current excess, A; 62 -* Delay before setting the error, millisecond; 63 -* Delay before clearing the error, second; 64 -* Lock – a flag to block the error until the device is restarted. 65 - 66 -=== Discharge current limit === 67 - 68 -The BMS Mini device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 69 - 70 -Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 71 - 72 -To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section: 73 - 74 -[[image:1740571296344-411.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="151" width="800"]] 75 - 76 -In this section: 77 - 78 -* Enable – a flag to enable the protection; 79 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 80 -* Region 1: Current difference – a value of maximum absolute current difference, A; 81 -* Region 2: Current difference – a value of maximum relative current excess, A; 82 -* Delay before setting the error, millisecond; 83 -* Delay before clearing the error, second; 84 -* Lock – a flag to block the error until the device is restarted. 85 - 86 86 === Undervoltage === 87 87 88 88 The BMS Mini device implements battery protection from too low voltage on the cells. ... ... @@ -89,7 +89,7 @@ 89 89 90 90 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 91 91 92 -[[image:1740 571345293-460.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]57 +[[image:1733748033237-837.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 93 93 94 94 In this section: 95 95 ... ... @@ -96,7 +96,6 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Minimum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 102 102 * Lock – a flag to block the error until the device is restarted. ... ... @@ -111,6 +111,11 @@ 111 111 112 112 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 113 113 78 +(% class="box infomessage" %) 79 +((( 80 +If there is the "Undervoltage" error, the **discharging **contactor opens. 81 +))) 82 + 114 114 === Overvoltage === 115 115 116 116 The BMS Mini device implements battery protection from too high voltage on the cells. ... ... @@ -117,7 +117,7 @@ 117 117 118 118 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 119 119 120 -[[image:1740 571383842-536.png]]89 +[[image:1733748033238-995.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 121 121 122 122 In this section: 123 123 ... ... @@ -139,6 +139,11 @@ 139 139 140 140 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 141 141 111 +(% class="box infomessage" %) 112 +((( 113 +If there is the "Overvoltage" error, the **charging **contactor and **discharging **contactor open (if the “Switch off the discharging contactor on error” flag is set). 114 +))) 115 + 142 142 === Low temperature === 143 143 144 144 The BMS Mini device implements battery protection from too low temperature. ... ... @@ -168,6 +168,11 @@ 168 168 169 169 * the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 170 170 145 +(% class="box infomessage" %) 146 +((( 147 +If there is the "Low temperature (CH)" error, the **charging **contactor opens. If there is the "Low temperature (DCH)" error, the **discharging **contactor opens. 148 +))) 149 + 171 171 === High temperature === 172 172 173 173 The BMS Mini device implements battery protection from too high temperature. ... ... @@ -197,6 +197,11 @@ 197 197 198 198 * the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 199 199 179 +(% class="box infomessage" %) 180 +((( 181 +If there is the "High temperature (CH)" error, the **charging **contactor opens. If there is the "High temperature (DCH)" error, the **discharging **contactor opens. 182 +))) 183 + 200 200 === Battery cover === 201 201 202 202 To change the protection parameters from opening the battery cover, select the "Protections → Battery cover" section: ... ... @@ -222,7 +222,7 @@ 222 222 223 223 (% class="box warningmessage" %) 224 224 ((( 225 -If there is the "Battery cover error", the **“Critical error” **is generated. 209 +If there is the "Battery cover error", the **“Critical error” **is generated **and all contactors open.** 226 226 ))) 227 227 228 228 === Cell monitor offline === ... ... @@ -250,7 +250,7 @@ 250 250 251 251 (% class="box warningmessage" %) 252 252 ((( 253 -If there is the " Cell monitor offline error", the **“Critical error” **is generated. 237 +If there is the " Cell monitor offline error", the **“Critical error” **is generated and** all contactors open.** 254 254 ))) 255 255 256 256 === Cell count === ... ... @@ -279,7 +279,7 @@ 279 279 280 280 (% class="box warningmessage" %) 281 281 ((( 282 -If there is the "Cell count error", the **“Critical error” **is generated. 266 +If there is the "Cell count error", the **“Critical error” **is generated and **all contactors open.** 283 283 ))) 284 284 285 285 === Short circuit === ... ... @@ -311,6 +311,11 @@ 311 311 312 312 * the current modulo is lower than the “Maximum current” values for all three protection levels during the “Delay before setting the error” time. 313 313 298 +(% class="box infomessage" %) 299 +((( 300 +If there is the "Short circuit" error, the **charging **contactor opens (the “Switch off the charging contactor on error” flag is set) and the **discharging **contactor opens (the “Switch off the discharging contactor on error flag” is set). 301 +))) 302 + 314 314 === High contactor temperature === 315 315 316 316 The BMS Mini device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X6 connector is used. ... ... @@ -374,7 +374,7 @@ 374 374 375 375 (% class="box warningmessage" %) 376 376 ((( 377 -If there is the “Current sensor error”, the **“Critical error” **is generated. 366 +If there is the “Current sensor error”, the **“Critical error” **is generated and** all contactors open.** 378 378 ))) 379 379 380 380 === Charge contactor cycles === ... ... @@ -405,6 +405,11 @@ 405 405 406 406 * the “Delay before clearing the error” time has passed since the error was generated. 407 407 397 +(% class="box infomessage" %) 398 +((( 399 +If there is the "CH contactor cycles error" error, the **charging** contactor opens. 400 +))) 401 + 408 408 === Discharge contactor cycles protection === 409 409 410 410 The BMS Mini device protects the discharging contactor against frequent switching. ... ... @@ -433,6 +433,11 @@ 433 433 434 434 * the “Delay before clearing the error” time has passed since the error was generated. 435 435 430 +(% class="box infomessage" %) 431 +((( 432 +If there is the "DCH contactor cycles error" error, the **discharging **contactor opens. 433 +))) 434 + 436 436 === Temperature sensors === 437 437 438 438 The BMS Mini device checks the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. ... ... @@ -452,7 +452,7 @@ 452 452 453 453 (% class="box warningmessage" %) 454 454 ((( 455 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated. 454 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all contactors open.** 456 456 ))) 457 457 458 458 === WDT reset === ... ... @@ -475,7 +475,7 @@ 475 475 476 476 (% class="box warningmessage" %) 477 477 ((( 478 -If there is the "WDT reset" error, the **“Critical error” **is generated. 477 +If there is the "WDT reset" error, the **“Critical error” **is generated and **all contactors open.** 479 479 ))) 480 480 481 481 === Unallowable charging === ... ... @@ -503,6 +503,11 @@ 503 503 504 504 * the battery current is zero during the “Delay before clearing the error” time. 505 505 505 +(% class="box infomessage" %) 506 +((( 507 +If there is the "Unallowable charging" error, the **discharging **contactor opens. 508 +))) 509 + 506 506 === Stuck contactor === 507 507 508 508 The BMS Mini device protects contactors against sticking. ... ... @@ -518,7 +518,7 @@ 518 518 * Delay before clearing the error, second; 519 519 * Lock – a flag to block the error until the device is restarted. 520 520 521 -If there is a stuck contactor, the “Stuck contactor” error is generated .Error generation conditions:525 +If there is a stuck contactor, the “Stuck contactor” error is generated Error generation conditions: 522 522 523 523 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 524 524 ... ... @@ -589,3 +589,8 @@ 589 589 * “Insulation fault”. 590 590 591 591 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 596 + 597 +(% class="box warningmessage" %) 598 +((( 599 +If there is the “Critical error”, **all contactors open.** 600 +)))
- 1740571132019-848.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.3 KB - Content
- 1740571296344-411.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.9 KB - Content
- 1740571345293-460.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.3 KB - Content
- 1740571383842-536.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content