Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -71,8 +71,18 @@ 71 71 72 72 To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section: 73 73 74 -[[image:1740571296344-411.png]] 74 +[[image:1740571296344-411.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="151" width="800"]] 75 75 76 +In this section: 77 + 78 +* Enable – a flag to enable the protection; 79 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 80 +* Region 1: Current difference – a value of maximum absolute current difference, A; 81 +* Region 2: Current difference – a value of maximum relative current excess, A; 82 +* Delay before setting the error, millisecond; 83 +* Delay before clearing the error, second; 84 +* Lock – a flag to block the error until the device is restarted. 85 + 76 76 === Undervoltage === 77 77 78 78 The BMS Mini device implements battery protection from too low voltage on the cells. ... ... @@ -79,7 +79,7 @@ 79 79 80 80 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 81 81 82 -[[image:17 33748033237-837.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]92 +[[image:1740571345293-460.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 83 83 84 84 In this section: 85 85 ... ... @@ -86,6 +86,7 @@ 86 86 * Enable – a flag to enable the protection; 87 87 * Minimum cell voltage, V; 88 88 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 89 89 * Delay before setting the error, millisecond; 90 90 * Delay before clearing the error, second; 91 91 * Lock – a flag to block the error until the device is restarted. ... ... @@ -106,7 +106,7 @@ 106 106 107 107 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 108 108 109 -[[image:17 33748033238-995.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]120 +[[image:1740571383842-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="800"]] 110 110 111 111 In this section: 112 112 ... ... @@ -113,9 +113,9 @@ 113 113 * Enable – a flag to enable the protection; 114 114 * Maximum cell voltage, V; 115 115 * Tolerant cell voltage, V; 127 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 116 116 * Delay before setting the error, millisecond; 117 117 * Delay before clearing the error, second; 118 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 119 119 * Lock – a flag to block the error until the device is restarted. 120 120 121 121 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -382,7 +382,6 @@ 382 382 * Delay before setting the error, millisecond; 383 383 * Delay before clearing the error, second; 384 384 * Lock – a flag to block the error until the device is restarted. 385 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 386 386 387 387 If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated. 388 388 ... ... @@ -400,7 +400,7 @@ 400 400 401 401 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 402 402 403 -[[image:17 33748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]]413 +[[image:1740571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]] 404 404 405 405 In this section: 406 406 ... ... @@ -410,7 +410,6 @@ 410 410 * Delay before setting the error, millisecond; 411 411 * Delay before clearing the error, second; 412 412 * Lock – a flag to block the error until the device is restarted. 413 -* Number of cycles – a number of the charging contactor switchings made during battery operation. 414 414 415 415 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 416 416 ... ... @@ -536,11 +536,15 @@ 536 536 537 537 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 538 538 539 -[[image:17 33748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]548 +[[image:1740573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]] 540 540 541 541 In this section: 542 542 543 543 * Enable – a flag to enable the protection; 553 +* Checking algorithm – isolation checking mode: 554 +** Always on – check is always performed; 555 +** On charging – check is performed only if “Charger connected” or “Charge request” is set; 556 +** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 544 544 * Delay before setting the error, second; 545 545 * Delay before clearing the error, second; 546 546 * Lock – a flag to block the error until the device is restarted. ... ... @@ -560,21 +560,26 @@ 560 560 * Delay before clearing the error, second; 561 561 * Lock – a flag to block the error until the device is restarted. 562 562 563 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:576 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 564 564 565 -* “Battery cover error”; 566 -* “Cell monitor offline”; 567 -* “Cell count error”; 568 -* “ADC error”; 569 -* “Current sensor error”; 570 -* “Shunt offline”; 571 -* “Shunt error”; 572 -* “No temp. sensors”; 573 -* “Temp. sensor is shorted”; 574 -* “Settings error”; 575 -* “WDT reset”; 576 -* “Stuck contactor”; 577 -* “Contactor feedback error”; 578 -* “Insulation fault”. 579 - 580 580 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 579 + 580 +=== General error === 581 + 582 +To change the general error parameters, select the "Protections → Critical error" section: 583 + 584 +[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 585 + 586 +In this section: 587 + 588 +* Enable – a flag to enable the protection; 589 +* Delay before setting the error, millisecond; 590 +* Delay before clearing the error, second; 591 +* Lock – a flag to block the error until the device is restarted; 592 +* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 593 + 594 +The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 595 + 596 +The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 597 + 598 +The state of the “General error” can be assigned to a discrete output or to a power switch.
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content