... ... @@ -63,6 +63,26 @@ 63 63 * Delay before clearing the error, second; 64 64 * Lock – a flag to block the error until the device is restarted. 65 65 66 +=== Discharge current limit === 67 + 68 +The BMS Mini device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 69 + 70 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 71 + 72 +To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section: 73 + 74 +[[image:1740571296344-411.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="151" width="800"]] 75 + 76 +In this section: 77 + 78 +* Enable – a flag to enable the protection; 79 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 80 +* Region 1: Current difference – a value of maximum absolute current difference, A; 81 +* Region 2: Current difference – a value of maximum relative current excess, A; 82 +* Delay before setting the error, millisecond; 83 +* Delay before clearing the error, second; 84 +* Lock – a flag to block the error until the device is restarted. 85 + 66 66 === Undervoltage === 67 67 68 68 The BMS Mini device implements battery protection from too low voltage on the cells. ... ... @@ -69,7 +69,7 @@ 69 69 70 70 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 71 71 72 -[[image:17 33748033237-837.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]92 +[[image:1740571345293-460.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 73 73 74 74 In this section: 75 75 ... ... @@ -76,6 +76,7 @@ 76 76 * Enable – a flag to enable the protection; 77 77 * Minimum cell voltage, V; 78 78 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 79 79 * Delay before setting the error, millisecond; 80 80 * Delay before clearing the error, second; 81 81 * Lock – a flag to block the error until the device is restarted. ... ... @@ -96,7 +96,7 @@ 96 96 97 97 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 98 98 99 -[[image:17 33748033238-995.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]120 +[[image:1740571383842-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="800"]] 100 100 101 101 In this section: 102 102 ... ... @@ -103,6 +103,7 @@ 103 103 * Enable – a flag to enable the protection; 104 104 * Maximum cell voltage, V; 105 105 * Tolerant cell voltage, V; 127 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 106 106 * Delay before setting the error, millisecond; 107 107 * Delay before clearing the error, second; 108 108 * Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
- 1740571345293-460.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.3 KB - Content
- 1740571383842-536.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content