... ... @@ -43,26 +43,7 @@ 43 43 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 44 44 * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 45 45 46 -=== Charge current limit === 47 47 48 -The BMS Mini device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 49 - 50 -Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 51 - 52 -To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section: 53 - 54 -[[image:1740571132019-848.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="143" width="800"]] 55 - 56 -In this section: 57 - 58 -* Enable – a flag to enable the protection; 59 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 60 -* Region 1: Current difference – a value of maximum absolute current difference, A; 61 -* Region 2: Current difference – a value of maximum relative current excess, A; 62 -* Delay before setting the error, millisecond; 63 -* Delay before clearing the error, second; 64 -* Lock – a flag to block the error until the device is restarted. 65 - 66 66 === Undervoltage === 67 67 68 68 The BMS Mini device implements battery protection from too low voltage on the cells. ... ... @@ -90,6 +90,7 @@ 90 90 91 91 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 92 92 74 + 93 93 === Overvoltage === 94 94 95 95 The BMS Mini device implements battery protection from too high voltage on the cells. ... ... @@ -384,6 +384,11 @@ 384 384 385 385 * the “Delay before clearing the error” time has passed since the error was generated. 386 386 369 +(% class="box infomessage" %) 370 +((( 371 +If there is the "CH contactor cycles error" error, the **charging** contactor opens. 372 +))) 373 + 387 387 === Discharge contactor cycles protection === 388 388 389 389 The BMS Mini device protects the discharging contactor against frequent switching. ... ... @@ -412,6 +412,11 @@ 412 412 413 413 * the “Delay before clearing the error” time has passed since the error was generated. 414 414 402 +(% class="box infomessage" %) 403 +((( 404 +If there is the "DCH contactor cycles error" error, the **discharging **contactor opens. 405 +))) 406 + 415 415 === Temperature sensors === 416 416 417 417 The BMS Mini device checks the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. ... ... @@ -431,7 +431,7 @@ 431 431 432 432 (% class="box warningmessage" %) 433 433 ((( 434 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated. 426 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all contactors open.** 435 435 ))) 436 436 437 437 === WDT reset === ... ... @@ -454,7 +454,7 @@ 454 454 455 455 (% class="box warningmessage" %) 456 456 ((( 457 -If there is the "WDT reset" error, the **“Critical error” **is generated. 449 +If there is the "WDT reset" error, the **“Critical error” **is generated and **all contactors open.** 458 458 ))) 459 459 460 460 === Unallowable charging === ... ... @@ -482,6 +482,11 @@ 482 482 483 483 * the battery current is zero during the “Delay before clearing the error” time. 484 484 477 +(% class="box infomessage" %) 478 +((( 479 +If there is the "Unallowable charging" error, the **discharging **contactor opens. 480 +))) 481 + 485 485 === Stuck contactor === 486 486 487 487 The BMS Mini device protects contactors against sticking. ... ... @@ -497,7 +497,7 @@ 497 497 * Delay before clearing the error, second; 498 498 * Lock – a flag to block the error until the device is restarted. 499 499 500 -If there is a stuck contactor, the “Stuck contactor” error is generated .Error generation conditions:497 +If there is a stuck contactor, the “Stuck contactor” error is generated Error generation conditions: 501 501 502 502 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 503 503 ... ... @@ -568,3 +568,8 @@ 568 568 * “Insulation fault”. 569 569 570 570 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 568 + 569 +(% class="box warningmessage" %) 570 +((( 571 +If there is the “Critical error”, **all contactors open.** 572 +)))
- 1740571132019-848.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.3 KB - Content
- 1740571296344-411.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.9 KB - Content