... ... @@ -252,36 +252,6 @@
252 252  If there is the "Battery cover error", the **“Critical error” **is generated.
253 253  )))
254 254  
255 -=== High board temperature ===
256 -
257 -BMS Mini monitors its temperature and disables the cell balancing when it overheats.
258 -
259 -To change the overheating protection parameters of BMS Mini device, select the "Protections → High board temperature" section:
260 -
261 -[[image:1777295045614-956.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]]In this section:
262 -
263 -* Enable – a flag to enable the protection;
264 -* Maximum temperature, °C;
265 -* Tolerant temperature, °C;
266 -* Delay before setting the error, second;
267 -* Delay before clearing the error, second;
268 -* Lock – lock the error until the device is reset.
269 -
270 -As a result of the operation of the protection from high temperatures of BMS Mini device, the "High board temperature" is generated.
271 -
272 -Error generation conditions:
273 -
274 -* a BMS Mini device temperature is higher than the “Maximum temperature” value.
275 -
276 -Conditions for removing the error:
277 -
278 -* a BMS Mini device temperature is less than the “Tolerant temperature” value.
279 -
280 -(% class="box infomessage" %)
281 -(((
282 -Cell balancing is disabled on BMS Mini device with high temperature.
283 -)))
284 -
285 285  === Cell monitor offline ===
286 286  
287 287  The BMS Mini device checks if there is connection with cell monitor and set an error if not.