... ... @@ -63,6 +63,26 @@
63 63  * Delay before clearing the error, second;
64 64  * Lock – a flag to block the error until the device is restarted.
65 65  
66 +=== Discharge current limit ===
67 +
68 +The BMS Mini device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated.
69 +
70 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference.
71 +
72 +To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section:
73 +
74 +[[image:1740571296344-411.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="151" width="800"]]
75 +
76 +In this section:
77 +
78 +* Enable – a flag to enable the protection;
79 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A;
80 +* Region 1: Current difference – a value of maximum absolute current difference, A;
81 +* Region 2: Current difference – a value of maximum relative current excess, A;
82 +* Delay before setting the error, millisecond;
83 +* Delay before clearing the error, second;
84 +* Lock – a flag to block the error until the device is restarted.
85 +
66 66  === Undervoltage ===
67 67  
68 68  The BMS Mini device implements battery protection from too low voltage on the cells.
... ... @@ -69,7 +69,7 @@
69 69  
70 70  To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section:
71 71  
72 -[[image:1733748033237-837.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]
92 +[[image:1740571345293-460.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
73 73  
74 74  In this section:
75 75  
... ... @@ -76,6 +76,7 @@
76 76  * Enable – a flag to enable the protection;
77 77  * Minimum cell voltage, V;
78 78  * Tolerant cell voltage, V;
99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
79 79  * Delay before setting the error, millisecond;
80 80  * Delay before clearing the error, second;
81 81  * Lock – a flag to block the error until the device is restarted.
... ... @@ -96,7 +96,7 @@
96 96  
97 97  To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section:
98 98  
99 -[[image:1733748033238-995.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
120 +[[image:1740571383842-536.png]]
100 100  
101 101  In this section:
102 102  
1740571296344-411.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +21.9 KB
Content
1740571345293-460.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +22.3 KB
Content
1740571383842-536.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content