Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -43,25 +43,7 @@ 43 43 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 44 44 * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 45 45 46 -=== Charge current limit === 47 47 48 -The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%203/3.%20Configuration/3.3%20Control/#HChargemap]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 49 - 50 -Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 51 - 52 -To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section: 53 - 54 - 55 -In this section: 56 - 57 -* Enable – a flag to enable the protection; 58 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 59 -* Region 1: Current difference – a value of maximum absolute current diffr, A; 60 -* Region 2: Current difference – a value of maximum relative current excess, A; 61 -* Delay before setting the error, millisecond; 62 -* Delay before clearing the error, second; 63 -* Lock – a flag to block the error until the device is restarted. 64 - 65 65 === Undervoltage === 66 66 67 67 The BMS Mini device implements battery protection from too low voltage on the cells. ... ... @@ -89,6 +89,7 @@ 89 89 90 90 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 91 91 74 + 92 92 === Overvoltage === 93 93 94 94 The BMS Mini device implements battery protection from too high voltage on the cells. ... ... @@ -383,6 +383,11 @@ 383 383 384 384 * the “Delay before clearing the error” time has passed since the error was generated. 385 385 369 +(% class="box infomessage" %) 370 +((( 371 +If there is the "CH contactor cycles error" error, the **charging** contactor opens. 372 +))) 373 + 386 386 === Discharge contactor cycles protection === 387 387 388 388 The BMS Mini device protects the discharging contactor against frequent switching. ... ... @@ -411,6 +411,11 @@ 411 411 412 412 * the “Delay before clearing the error” time has passed since the error was generated. 413 413 402 +(% class="box infomessage" %) 403 +((( 404 +If there is the "DCH contactor cycles error" error, the **discharging **contactor opens. 405 +))) 406 + 414 414 === Temperature sensors === 415 415 416 416 The BMS Mini device checks the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. ... ... @@ -430,7 +430,7 @@ 430 430 431 431 (% class="box warningmessage" %) 432 432 ((( 433 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated. 426 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all contactors open.** 434 434 ))) 435 435 436 436 === WDT reset === ... ... @@ -453,7 +453,7 @@ 453 453 454 454 (% class="box warningmessage" %) 455 455 ((( 456 -If there is the "WDT reset" error, the **“Critical error” **is generated. 449 +If there is the "WDT reset" error, the **“Critical error” **is generated and **all contactors open.** 457 457 ))) 458 458 459 459 === Unallowable charging === ... ... @@ -481,6 +481,11 @@ 481 481 482 482 * the battery current is zero during the “Delay before clearing the error” time. 483 483 477 +(% class="box infomessage" %) 478 +((( 479 +If there is the "Unallowable charging" error, the **discharging **contactor opens. 480 +))) 481 + 484 484 === Stuck contactor === 485 485 486 486 The BMS Mini device protects contactors against sticking. ... ... @@ -496,7 +496,7 @@ 496 496 * Delay before clearing the error, second; 497 497 * Lock – a flag to block the error until the device is restarted. 498 498 499 -If there is a stuck contactor, the “Stuck contactor” error is generated .Error generation conditions:497 +If there is a stuck contactor, the “Stuck contactor” error is generated Error generation conditions: 500 500 501 501 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 502 502 ... ... @@ -567,3 +567,8 @@ 567 567 * “Insulation fault”. 568 568 569 569 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 568 + 569 +(% class="box warningmessage" %) 570 +((( 571 +If there is the “Critical error”, **all contactors open.** 572 +)))
- 1740571132019-848.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.3 KB - Content