... ... @@ -256,28 +256,8 @@
256 256  
257 257  BMS Mini monitors its temperature and disables the cell balancing when it overheats.
258 258  
259 -To change the overheating protection parameters of BMS Mini device, select the "Protections → High board temperature" section:
259 +To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section:
260 260  
261 -
262 -In this section:
263 -
264 -* Enable – a flag to enable the protection;
265 -* Maximum temperature, °C;
266 -* Tolerant temperature, °C;
267 -* Delay before setting the error, second;
268 -* Delay before clearing the error, second;
269 -* Lock – lock the error until the device is reset.
270 -
271 -As a result of the operation of the protection from high temperatures of BMS Mini device, the "High board temperature" is generated.
272 -
273 -Error generation conditions:
274 -
275 -* a BMS Mini device temperature is higher than the “Maximum temperature” value.
276 -
277 -Conditions for removing the error:
278 -
279 -* a BMS Mini device temperature is less than the “Tolerant temperature” value.
280 -
281 281  === Cell monitor offline ===
282 282  
283 283  The BMS Mini device checks if there is connection with cell monitor and set an error if not.