... ... @@ -252,32 +252,6 @@
252 252  If there is the "Battery cover error", the **“Critical error” **is generated.
253 253  )))
254 254  
255 -=== High board temperature ===
256 -
257 -BMS Mini monitors its temperature and disables the cell balancing when it overheats.
258 -
259 -To change the overheating protection parameters of BMS Mini device, select the "Protections → High board temperature" section:
260 -
261 -
262 -In this section:
263 -
264 -* Enable – a flag to enable the protection;
265 -* Maximum temperature, °C;
266 -* Tolerant temperature, °C;
267 -* Delay before setting the error, second;
268 -* Delay before clearing the error, second;
269 -* Lock – lock the error until the device is reset.
270 -
271 -As a result of the operation of the protection from high temperatures of BMS Mini device, the "High board temperature" is generated.
272 -
273 -Error generation conditions:
274 -
275 -* a BMS Mini device temperature is higher than the “Maximum temperature” value.
276 -
277 -Conditions for removing the error:
278 -
279 -* a BMS Mini device temperature is less than the “Tolerant temperature” value.
280 -
281 281  === Cell monitor offline ===
282 282  
283 283  The BMS Mini device checks if there is connection with cell monitor and set an error if not.