Changes for page 3.4 Protections

Last modified by Admin on 2026/04/27 13:04

From version 28.3
edited by Admin
on 2026/04/27 13:03
Change comment: There is no comment for this version
To version 25.1
edited by Admin
on 2025/11/10 11:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -252,32 +252,6 @@
252 252  If there is the "Battery cover error", the **“Critical error” **is generated.
253 253  )))
254 254  
255 -=== High board temperature ===
256 -
257 -BMS Mini monitors its temperature and disables the cell balancing when it overheats.
258 -
259 -To change the overheating protection parameters of BMS Mini device, select the "Protections → High board temperature" section:
260 -
261 -
262 -In this section:
263 -
264 -* Enable – a flag to enable the protection;
265 -* Maximum temperature, °C;
266 -* Tolerant temperature, °C;
267 -* Delay before setting the error, second;
268 -* Delay before clearing the error, second;
269 -* Lock – lock the error until the device is reset.
270 -
271 -As a result of the operation of the protection from high temperatures of BMS Mini device, the "High board temperature" is generated.
272 -
273 -Error generation conditions:
274 -
275 -* a BMS Mini device temperature is higher than the “Maximum temperature” value.
276 -
277 -Conditions for removing the error:
278 -
279 -* a BMS Mini device temperature is less than the “Tolerant temperature” value.
280 -
281 281  === Cell monitor offline ===
282 282  
283 283  The BMS Mini device checks if there is connection with cell monitor and set an error if not.
... ... @@ -679,7 +679,7 @@
679 679  
680 680  To change the critical error parameters, select the "Protections → Critical error" section:
681 681  
682 -[[image:1762775067035-203.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="143" width="800"]]
656 +[[image:1733748083469-183.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
683 683  
684 684  In this section:
685 685  
... ... @@ -686,7 +686,6 @@
686 686  * Enable – a flag to enable the protection;
687 687  * Delay before setting the error, millisecond;
688 688  * Delay before clearing the error, second;
689 -* Errors 1,2 to ignore when setting the critical error;
690 690  * Lock – a flag to block the error until the device is restarted.
691 691  
692 692  The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
1762775067035-203.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.4 KB
Content
1777294625990-675.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -14.8 KB
Content