Changes for page 3.4 Protections
Last modified by Admin on 2026/04/27 13:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -252,12 +252,6 @@ 252 252 If there is the "Battery cover error", the **“Critical error” **is generated. 253 253 ))) 254 254 255 -=== High board temperature === 256 - 257 -BMS Mini monitors its temperature and disables the cell balancing when it overheats. 258 - 259 -To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 260 - 261 261 === Cell monitor offline === 262 262 263 263 The BMS Mini device checks if there is connection with cell monitor and set an error if not. ... ... @@ -439,24 +439,6 @@ 439 439 If there is the “Current sensor error”, the **“Critical error” **is generated. 440 440 ))) 441 441 442 -=== MOSFET === 443 - 444 -BMS Mini S device checks the status of MOSFET switches that are used to control the contactors. To change the parameters of the MOSFET switch protection, select the "Protections → MOSFET " section: 445 - 446 -[[image:1762773566548-852.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]] 447 - 448 -In this section: 449 - 450 -* Delay before clearing the error, second; 451 -* Lock – a flag to block the error until the device is restarted. 452 - 453 -The “MOSFET error” occurs when the device detects a shortage in contactor coil control circuit or an overheating of the MOSFET switch. Error is removed when the temperature of MOSFET switch is normal during “Delay before clearing the error” time. 454 - 455 -(% class="box warningmessage" %) 456 -((( 457 -If there is the "MOSFET error", the **“Critical error” **is generated. 458 -))) 459 - 460 460 === Charge contactor cycles === 461 461 462 462 The BMS Mini device protects the charging contactor against frequent switching. ... ... @@ -484,7 +484,7 @@ 484 484 485 485 * the “Delay before clearing the error” time has passed since the error was generated. 486 486 487 -=== Discharge contactor cycles === 463 +=== Discharge contactor cycles protection === 488 488 489 489 The BMS Mini device protects the discharging contactor against frequent switching. 490 490 ... ... @@ -659,7 +659,7 @@ 659 659 660 660 To change the critical error parameters, select the "Protections → Critical error" section: 661 661 662 -[[image:17 62775067035-203.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="143" width="800"]]638 +[[image:1733748083469-183.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] 663 663 664 664 In this section: 665 665 ... ... @@ -666,7 +666,6 @@ 666 666 * Enable – a flag to enable the protection; 667 667 * Delay before setting the error, millisecond; 668 668 * Delay before clearing the error, second; 669 -* Errors 1,2 to ignore when setting the critical error; 670 670 * Lock – a flag to block the error until the device is restarted. 671 671 672 672 The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
- 1762773566548-852.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.1 KB - Content
- 1762775067035-203.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content
- 1777294625990-675.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.8 KB - Content