... ... @@ -252,6 +252,32 @@
252 252  If there is the "Battery cover error", the **“Critical error” **is generated.
253 253  )))
254 254  
255 +=== High board temperature ===
256 +
257 +BMS Mini monitors its temperature and disables the cell balancing when it overheats.
258 +
259 +To change the overheating protection parameters of BMS Mini device, select the "Protections → High board temperature" section:
260 +
261 +
262 +In this section:
263 +
264 +* Enable – a flag to enable the protection;
265 +* Maximum temperature, °C;
266 +* Tolerant temperature, °C;
267 +* Delay before setting the error, second;
268 +* Delay before clearing the error, second;
269 +* Lock – lock the error until the device is reset.
270 +
271 +As a result of the operation of the protection from high temperatures of BMS Mini device, the "High board temperature" is generated.
272 +
273 +Error generation conditions:
274 +
275 +* a BMS Mini device temperature is higher than the “Maximum temperature” value.
276 +
277 +Conditions for removing the error:
278 +
279 +* a BMS Mini device temperature is less than the “Tolerant temperature” value.
280 +
255 255  === Cell monitor offline ===
256 256  
257 257  The BMS Mini device checks if there is connection with cell monitor and set an error if not.