Changes for page 3.4 Protections
Last modified by Admin on 2026/04/27 13:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -252,6 +252,36 @@ 252 252 If there is the "Battery cover error", the **“Critical error” **is generated. 253 253 ))) 254 254 255 +=== High board temperature === 256 + 257 +BMS Mini monitors its temperature and disables the cell balancing when it overheats. 258 + 259 +To change the overheating protection parameters of BMS Mini device, select the "Protections → High board temperature" section: 260 + 261 +[[image:1777295045614-956.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]]In this section: 262 + 263 +* Enable – a flag to enable the protection; 264 +* Maximum temperature, °C; 265 +* Tolerant temperature, °C; 266 +* Delay before setting the error, second; 267 +* Delay before clearing the error, second; 268 +* Lock – lock the error until the device is reset. 269 + 270 +As a result of the operation of the protection from high temperatures of BMS Mini device, the "High board temperature" is generated. 271 + 272 +Error generation conditions: 273 + 274 +* a BMS Mini device temperature is higher than the “Maximum temperature” value. 275 + 276 +Conditions for removing the error: 277 + 278 +* a BMS Mini device temperature is less than the “Tolerant temperature” value. 279 + 280 +(% class="box infomessage" %) 281 +((( 282 +Cell balancing is disabled on BMS Mini device with high temperature. 283 +))) 284 + 255 255 === Cell monitor offline === 256 256 257 257 The BMS Mini device checks if there is connection with cell monitor and set an error if not. ... ... @@ -653,7 +653,7 @@ 653 653 654 654 To change the critical error parameters, select the "Protections → Critical error" section: 655 655 656 -[[image:17 33748083469-183.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]686 +[[image:1762775067035-203.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="143" width="800"]] 657 657 658 658 In this section: 659 659 ... ... @@ -660,6 +660,7 @@ 660 660 * Enable – a flag to enable the protection; 661 661 * Delay before setting the error, millisecond; 662 662 * Delay before clearing the error, second; 693 +* Errors 1,2 to ignore when setting the critical error; 663 663 * Lock – a flag to block the error until the device is restarted. 664 664 665 665 The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
- 1777294625990-675.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.8 KB - Content
- 1777295045614-956.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.8 KB - Content