... ... @@ -433,24 +433,6 @@
433 433  If there is the “Current sensor error”, the **“Critical error” **is generated.
434 434  )))
435 435  
436 -=== MOSFET ===
437 -
438 -BMS Mini S device checks the status of MOSFET switches that are used to control the contactors. To change the parameters of the MOSFET switch protection, select the "Protections → MOSFET " section:
439 -
440 -[[image:1762773566548-852.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]
441 -
442 -In this section:
443 -
444 -* Delay before clearing the error, second;
445 -* Lock – a flag to block the error until the device is restarted.
446 -
447 -The “MOSFET error” occurs when the device detects a shortage in contactor coil control circuit or an overheating of the MOSFET switch. Error is removed when the temperature of MOSFET switch is normal during “Delay before clearing the error” time.
448 -
449 -(% class="box warningmessage" %)
450 -(((
451 -If there is the "MOSFET error", the **“Critical error” **is generated.
452 -)))
453 -
454 454  === Charge contactor cycles ===
455 455  
456 456  The BMS Mini device protects the charging contactor against frequent switching.
... ... @@ -478,7 +478,7 @@
478 478  
479 479  * the “Delay before clearing the error” time has passed since the error was generated.
480 480  
481 -=== Discharge contactor cycles ===
463 +=== Discharge contactor cycles protection ===
482 482  
483 483  The BMS Mini device protects the discharging contactor against frequent switching.
484 484  